ARCMASTER 185 AC/DC
Feb
r
ua
r
y 20, 2006
7-3
7.05 Guide for Selecting Filler Wire Diameter
NOTE
The fille
r
wi
r
e diamete
r
specified in Table 7-4 is a guide only, othe
r
diamete
r
wi
r
es may be used acco
r
ding
to the welding application
AC Current Range
DC Current Range
(Amps)
(Amps)
1/16” (1.6 mm)
30 - 95
20 - 90
3/32” (2.4 mm)
125 - 160
65 - 115
1/8” (3.2 mm)
180 - 240
100 - 165
3/16” (4.8 mm)
220 - 320
200 - 350
Filler Wire Diameter
Table 7-4: Fille
r
Wi
r
e Selection Guide
7.06 Shielding Gas Selection
Shielding Gas
A
r
goshield is a
r
egiste
r
ed t
r
adema
r
k of BOC Gases Limited.
Aluminium & alloys
Welding A
r
gon, A
r
goshield 80T, 81T
Ca
r
bon Steel
Welding A
r
gon
Stainless Steel
Welding A
r
gon, A
r
goshield 71T, 80T, 81T
Nickel Alloy
Welding A
r
gon, A
r
goshield 71T
Coppe
r
Welding A
r
gon, A
r
goshield 81T
Titanium
Welding A
r
gon, A
r
goshield 80T, 81T
Alloy
Table 7-5: Shielding Gas Selection
7.07 TIG Welding Parameters for Low Carbon & Low Alloy Steel Pipe
Current Range DC
Amperes
Tho
r
iated 2%
3/32” (2.4 mm)
Tho
r
iated 2%
3/32” (2.4 mm)
Tho
r
iated 2%
3/32” (2.4 mm)
Electrode Type &
Diameter
Filler Rod for
Root Pass
Joint Preparation
120 - 170
Yes
100 - 160
Yes
90 - 130
No
Table 7-6: TIG Welding Pa
r
amete
r
s fo
r
Low Ca
r
bon & Low Alloy Steel Pipe
Содержание ARCMASTER 185 AC/DC
Страница 24: ...ARCMASTER 185 AC DC 3 6 February 20 2006 NOTES ...
Страница 34: ...ARCMASTER 185 AC DC 5 2 February 20 2006 NOTES ...
Страница 58: ...ARCMASTER 185 AC DC 11 4 February 20 2006 NOTES ...
Страница 69: ......
Страница 72: ......