INSTALLATION
THERMAL ARC 95 S
Installation
3-3
Manual 0-5086
Input Power
Each unit incorporates an INRUSH circuit. When the MAIN CIRCUIT SWITCH is turned on, the inrush circuit provides
pre-charging for the input capacitors. A relay in the Power Control Assembly (PCA) will turn on after the input capacitors
have charged to operating voltage (after approximately 5 seconds)
NOTE
Damage to the PCA could occur if 133 VAC or higher is applied to the Primary Power Cable.
Table 3-2: Primary Circuit Sizes to Achieve Maximum Current
Model
Primary Supply Lead Size
(Factory Fitted)
Minimum Primary
Current Circuit Size
(Vin/Amps)
Current & Duty Cycle
TIG
STICK
Thermal Arc 95 S
12 AWG (3.3mm²)
115V/30A
-
90A / 23.6V @ 20%
115V/21A
95A / 13.8V @ 20%
-