INSTALLATION/SETUP 202 AC/DC INVERTER
INSTALLATION, OPERATION AND SETUP
3-14
Manual 0-5239
2. The regulator body will be stamped “IN” or “HP” at the inlet port. Attach the inlet port to the system
supply pressure connection.
3. Wrap pipe threads with Teflon tape 1 1/2 to 2 turns to effect a seal. If other sealants are used, they
must be compatible with the gas that will be used in the system.
4. If gauges are to be attached to the regulator and the regu lator is stamped and listed by a third party
(i.e. “UL” or “ETL”). The following requirements must be met:
a) Inlet gauges over 1000 PSIG (6.87 mPa) shall conform with the requirements of UL 404, “Indicating
Pressure Gauges for Compressed Gas Service.”
b) Low pressure gauges must be UL recognized for the class of regulator they are being used on ac-
cording to UL252A.
!
WARNING
DO NOT use a regulator that delivers pressure exceeding the pressure rating of the downstream
equipment unless pro visions are made to prevent over-pressurization (i.e. system relief valve).
Make sure the pressure rating of the down stream equipment is compatible with the maximum
delivery pressure of the regulator.
5. Be sure that the regulator has the correct pressure rating and gas service for the cylinder used.
6. Carefully inspect the regulator for damaged threads, dirt, dust, grease, oil, or other flammable
substances. Remove dust and dirt with a clean cloth. Be sure the inlet swivel filter is clean and in place.
Attach the regulator (Figure 3-8) to the cylinder valve. Tighten securely with a wrench.
!
WARNING
DO NOT attach or use the regulator if oil, grease, flamma ble substances or damage is present!
Have a qualified repair technician clean the regulator or repair any damage.
Art # A-09845
Figure 3-8: Regulator to Cylinder Valve
7. Before opening the cylinder valve, turn the regulator adjusting screw counterclockwise until there is
no pressure on the adjusting spring and the screw turns freely.
8. Relief Valve (where provided): The relief valve is designed to protect the low pressure side of the
regulator from high pres sures. Relief valves are not intended to protect down stream equipment from
high pressures.
!
WARNING
DO NOT tamper with the relief valve or remove it from the regulator.