APPENDIX 4 DIODE TESTING BASICS
A11
APPENDIX 4 DIODE TESTING BASIC
DIODE TESTING BASIC
Testing of diode modules requires a digital Volt/
Ohmmeter that has a diode test scale.Locate the
diode module to be tested.Remove cables from
mounting studs on diodes to isolate them within the
module.Set the digital volt/ohm meter to the diode
test scale.Using figure 1 and 2, check each diode
in the module. Each diode must be checked in both
the forward bias (positive to negative) and reverse
bias (negative to positive) direction.
1. To check the diode in the forward bias direc-
tion, connect the volt/ohm meter positive lead
to the anode (positive, +) of the diode and the
negative lead to the cathode (negative, –) of
the diode (refer to Figure 13-1
. A properly
functioning diode will conduct in the forward
bias direction, and will indicate between 0.3
and 0.9 volts.
2. To check the diode in the reverse bias direc-
tion, reverse the meter leads (refer to Figure
13-1). A properly functioning diode will block
current flow in the reverse bias direction, and
depending on the meter function, will indicate
an open or "OL".
3. If any diode in the module tests as faulty,
replace the diode module.
4. Reconnect all cables to the proper terminals.
Figure 13-1: Forward bias diode test
Figure 13-2: Reverse bias diode test
COM
A
VR
Anode
Cathode
Forward Bias
Diode Conducting
COM
A
VR
Anode
Cathode
Reverse Bias
Diode Not Conducting
Содержание 185 AC
Страница 2: ......
Страница 20: ...2 6 May 22 2006 ARCMASTER 185 ACDC 200 ACDC...
Страница 26: ...3 6 May 22 2006 ARCMASTER 185 ACDC 200 ACDC...
Страница 34: ...5 2 May 22 2006 ARCMASTER 185 ACDC 200 ACDC...
Страница 50: ...9 4 May 22 2006 ARCMASTER 185 ACDC 200 ACDC...
Страница 105: ......
Страница 117: ......
Страница 120: ......