![Thermal Arc 160 TS ARCMASTER Скачать руководство пользователя страница 60](http://html1.mh-extra.com/html/thermal-arc/160-ts-arcmaster/160-ts-arcmaster_service-manual_1103141060.webp)
ARCMASTER 160TS
56
11.02 Verification and Remedy to the Indicated Error Codes
Note
The capacitors inside the power supply will slowly discharged after you turn off the switch
of the power supply or the switch at the breaker box (distribution panel). Wait at least 5
minutes for the discharge to complete and then remove the cases to continue your
inspection and repair (or maintenance) inside the power supply. As for the removal and
installation of the case, refer to section 11.01.1.
Note
During the “
Verification/Remedy
” procedures below, follow the alphabetical sequence (a, b,
c…) and proceed with your verification and confirmation.
Note
After you Verify and replace all spare parts and components, Verify that there are no
damaged harnesses or connectors, uninstalled or loose screws.