![Thermadyne CE CutMaster 51 Скачать руководство пользователя страница 49](http://html1.mh-extra.com/html/thermadyne/ce-cutmaster-51/ce-cutmaster-51_operating-manual_1103097049.webp)
Manual 0-2989
A-1
APPENDIX
APPENDIX 1: SEQUENCE OF OPERATION
(BLOCK DIAGRAM)
ACTION:
ON / OFF switch to ON
RESULT:
AC indicator ON.
Fan(s) ON.
GAS indicator ON
when input
pressure is adequate
for power supply operation.
Power circuit ready.
ACTION:
Protect eyes and activate torch.
RESULT:
Gas flows briefly, then stops.
Gas restarts.
DC indicator ON
Pilot arc established.
Art #A-03706A
ACTION:
Unplug input
power cord or
open external
disconnect.
RESULT:
No power to system.
ACTION:
Connect work cable to workpiece.
Set output amperage.
RESULT:
System is ready
for operation.
ACTION:
RUN /
Rapid Auto Restart /
SET switch
to SET
RESULT:
Gas flows to set pressure.
ACTION:
RUN /
Rapid Auto Restart / SET
switch to RUN
(for most applications)
or to
Rapid Auto Restart
(for gouging, trimming,
or expanded metal
applications)
RESULT:
Gas flow stops.
ACTION:
Release torch trigger.
RESULT:
Main arc stops.
Gas flow stops after post - flow.
ACTION:
ON / OFF switch
to OFF
RESULT:
All indicators off.
Power supply fan(s) shuts off.
ACTION:
Close external
disconnect switch.
RESULT:
Power to system.
ACTION:
Torch moved within
transfer distance of workpiece.
RESULT:
Main arc transfers.
Pilot arc off.
PILOT ARC
ACTION:
Torch moved away from work (while
still activated).
RESULT:
Main arc stops.
Pilot arc automatically
restarts.
Содержание CE CutMaster 51
Страница 1: ...Plasma Cutting Power Supply CE CutMaster 51 Operating Manual January 12 2004 Manual No 0 2989 A 03688...
Страница 2: ......
Страница 6: ......
Страница 48: ...PARTS LISTS 6 4 Manual 0 2989...
Страница 56: ......