Installation and connection
en-us
7
Before using for the first time
1.
Remove information material, adhesive tape and
protective foil.
2.
Clean the appliance.
Electrical connection
9
CAUTION
Do not connect the appliance to electronic
energy saver plugs.
Note:
You can connect the appliance to mains-
controlled and sine-controlled inverters.
Mains-controlled inverters are used for photovoltaic
systems which are connected directly to the national
grid. Sine-controlled inverters must be used for
isolated applications. Isolated applications, e.g. on
ships or in mountain lodges, are not directly
connected to the national grid.
1.
After installing the appliance, wait at least 1 hour
before connecting it to prevent damaging the
compressor.
2.
Check that the outlet was installed according to
the regulations and complies with the
requirements.
Requirements for outlets
Maximum simultaneous load
3.
Connect the appliance to an outlet near the
appliance.
The outlet must also be freely accessible
following installation of the appliance.
9
WARNING
RISK OF ELECTRIC SHOCK!
Never use multiple outlets, extension leads
or adapters.
The appliance must be grounded correctly.
Never cut through or remove the power
cord's third conductor (grounding
conductor).
9
WARNING
RISK OF ELECTRIC SHOCK!
If the power cord is too short, never use
multiple outlets or extension leads.Instead,
please contact Customer Service.
Outlet with
110 V ... 120 V
Protective conductor
60 Hz
Fuse
10 A ... 16 A
Appliance
6 A