Service Manual for the Thermador Professional Series Rangetop, Model PCG366G
58300000151625_ARA_EN_B
Page 26 of 34
9. Remove the white plastic side connector from the potentiometer
by pressing on the connector’s tab. (see Figure 34).
Figure 34: Side Connector Tab
10. Detach the XLO valve from the potentiometer by using a small
flat-blade screwdriver to gently remove the XLO valve from the
potentiometer standoffs. Then slide the potentiometer off the valve
stem (see Figure 35).
11. Replace the XLO valve if needed.
Figure 35: Removing the XLO Valve from the Potentiometer
Gas Leaks
Carefully check for gas leaks at each gas component that was
removed, replaced, or otherwise serviced using a gas leak detector or
bubble test.
Side
connector tab