Service Manual for the Thermador Pro Harmony Range, Model PRL364GDH/01
58300000154022_ARA_EN_D
Page 67 of 68
4. Remove the thermostat from the back of the control panel
(see Figure 132).
Figure 132: Thermostat (Typical Model Shown)
7 BEFORE RETURNING APPLIANCE TO SERVICE
After you have finished all testing and servicing, always do the
following before returning the appliance to service:
■ Carefully check for gas leaks at each gas component that was
removed, replaced, or otherwise serviced using a gas leak
detector or bubble test.
■ Make sure all electrical connections are correct and secure.
■ Make sure all safety grounds (internal and external) are correctly
and securely connected.
■ Make sure all panels and components are properly and securely
reassembled.
■ Make sure the range is level and adjust accordingly.
■ If the range was pulled away from the wall for servicing, cleaning,
or any other reason, make sure that the range is properly secured
onto the anti-tip device when the range is pushed back against the
wall. Refer to the Installation Manual for details on anti-tip device
installation.
8 CLEAN-UP
After you have finished servicing an appliance, clean up grease,
fingerprints, and other residue that is present as the result of servicing
the appliance.
Clean-up Hazards
Don’t allow any cleaning or polishing solutions/compounds,
disinfectants or bleaches to remain in contact with the stainless steel
surfaces for long periods, or after clean-up. These may contain
chemicals or materials which could release harmful inhalants or may
damage the appliance. After cleaning or polishing, always rinse the
cleaning/polishing materials with clear water and wipe dry with a
clean, soft, non-abrasive cloth.