6.3.8
Temperature Selector Removal and Replacement
Figure 57: Temperature Selector and Knob
NOTE:
For PRL364GDH/01, the Temperature Selector may or may
not be secured to the back of the control panel with a clamp. If a
clamped Temperature Selector needs replacing, the replacement part
(used without clamp) is fully compatible.
1. Follow all safety precautions and steps in
, page
2. Follow all steps in
Accessing Components under the Maintop
3. Remove knob from valve stem by slowly pulling knob straight out,
away from control panel.
4. From the back of the control panel, first make a note of how the
connector wires are connected to the Temperature Selector
terminals, and then remove the wires from the terminals
(see Figure 59).
NOTE:
It is always recommended to label and tag all wires and
harnesses prior to disconnecting them, so as to correctly identify
their connections/locations when reassembling.
HINT:
Alternatively, you can photograph the wire connections
prior to disconnecting (for example, with your mobile phone).
5. From the front of the control panel, remove and retain the two
screws on the bezel which are attached to the Temperature
Selector (see Figure 58).
Figure 58: Temperature Selector Screws on Bezel
6. Remove the blade connectors from the Temperature Selector at
the back side of the control panel (see Figure 59).
Figure 59: Temperature Selector