Service Manual for Thermador Pro Grand LP Gas Ranges, Models: PRL304EG, PRL364EDG, PRL364ELG, PRL366EG, PRL484ECG, PRL486EDG, PRL486EDPG, PRL484ELG
58300000156573_ARA_EN_B
Page 66 of 119
Figure 123: Removing the Door Latch
1 Plunger
switch
9. Detach the spade wire connectors from the latch and the white
plastic piggyback wire connector on the door latch’s microswitch
(see Figure 124, page 66).
NOTE:
It is always recommended to label and tag all wires, wire
connectors, and harnesses prior to disconnecting them so as to
correctly identify their connections/locations when re-assembling.
Alternatively, you can photograph prior to disconnecting (for
example, with your mobile phone).
Figure 124: Door Latch (Shown Removed from Cavity)
1
Spade connectors (2)
2
Piggyback wire connector
3 Door
latch
10. Replace the door latch if needed.
NOTE:
If replacing the plunger switch, it must be done before the
door latch is re-installed (see
page
).