Service Manual for the Thermador Pro Grand Next Generation 48-Inch Natural Gas and LP Gas Ranges, Models:
PRG486JDG/01, PRL486JDG/01
58300000159722_ARA_EN_D
Page 50 of 92
5. At the front of the range, pull the temperature gauge outward to
remove it, and then detach the wire connector (see Figure 68).
Figure 68: Detaching the Wire Connector (Shown with Temperature
Gauge Removed)
6. Replace the temperature gauge if necessary.
6.7.14
Control Boards for Large and Small Ovens – Removal
and Replacement
This procedure is for the oven control boards for both the large
and small ovens.
Be sure to check QuickFinder for relevant information, documentation,
and the correct part number when replacing this component.
1. Follow all safety precautions and steps in
2. Follow all steps in
Accessing Components under the Maintop
3. Remove the griddle in order to gain access to the main control
board (see
Griddle / Grill Removal and Replacement,
page
Figure 69: Cover Shield
1
Screws (2) on cover shield
4. Remove and retain the two screws attaching the cover shield to
the range chassis (see Figure 69).
5. Remove all multi-pin wire connectors from the control board as
well as the spade connector of the ground wire (see Figure 70,
page 51).
NOTE:
It is always recommended to label and tag all wires, wire
connectors, and harnesses prior to disconnecting them so as to
correctly identify their connections/locations when reassembling.
Alternatively, you can photograph prior to disconnecting (for
example, with your mobile phone).