DWHD651GFP
DISHWASHER & CUTOUT DIMENSIONS
WATER AND ELECTRICAL
LOCATIONS
For proper dishwasher operation and
appearance, ensure that the enclosure is square
and has the dimensions shown. Plumbing and
electrical service must enter shaded area.
Make required openings to allow for passage
of the water, drain and electrical line. In order
to avoid interference with the dishwasher when
sliding it into the cabinet, place your openings
within the dimensions shown.
Sapphire Series Required Openings:
4
1
/
4
" x 2" (108 x 52 mm) - To pass the
included electrical supply junction box
through to an adjacent cabinet
4" x 2" (100 x 50 mm) - To pass the included
water supply line toward the water supply
1
1
/
4
" (32 mm) diameter - To pass the
dishwasher drain hose toward the drain
connection
NOTE:
If the incoming electric supply, water
supply and drain connections are all in the
same cabinet, the one 4
1
/
2
" x 2
1
/
2
" hole will
be large enough for all three to pass through.
The dishwasher electrical supply junction box
and dedicated receptacle must be mounted
in an accessible cabinet adjacent to the
dishwasher (do not mount the junction box
or receptacle behind the dishwasher). You
will need a 4
1
/
4
" x 2" (108 x 51 mm) opening
through the cabinet in order to pass the
junction box through.
The electrical supply can be connected in one
of two ways:
– Use the included three prong plug and
junction box to connect to a dedicated
household receptacle.
– Permanently connect to household or
field wiring
90°
24" (61cm)
2" (5
cm)
34¼"(86.7cm)
4" (10
cm)
24"-24
¼" (61-61.6 cm)
Electric cord with
junction box and
three prong plug
are included
with dishwasher
Dedicated
Receptacle or
Field Wiring
Dishwasher
Electrical Supply
Junction Box
Dishwasher
Water Inlet
Hose
Water
Shut Off
Valve
WATER AND ElECTRICAl lOCATION DIMENSIONS
Describes the space (if any) between
cabinets and wall
Describes the cutout of adjoining cabinets