Thermador An American Icon PH30ZS Скачать руководство пользователя страница 10

PHZ Service Manual

PAGE 8

Operating Instructions

The blower should be turned on for about  5 minutes
before cooking in order to establish air currents
upward through the hood.  Thus when heat, smoke,
moisture, grease and cooking odors are produced,
they will be carried outside instead of drifting into

Hood Operating Instructions

other rooms.  Use the low speeds for normal use
and the higher speeds for strong odors or fumes.

Drafts across the range or cooktop will reduce the
effectiveness of the hood.  Such drafts should be
prevented when possible.

1

2

3

OFF BUTTON – Pressing button once turns
ventilator off and resets control.

FAN SPEED BUTTON – Pressing button once,
from an off state, turns the ventilator on low.
Each successive press of the button increases
the fan speed until high where the fan cycles
back to the low speed.

The LEDs above this button indicate the
current fan speed.  When the fan is on, the
corresponding LED is illuminated.

1 – Low
2 – Medium
3 – High

DELAY SHUT OFF BUTTON –

Press to turn fan on high for 10 minutes.

If the ventilator is off when the delay button is
pressed, the ventilator will turn on to the high
speed setting for 10 minutes.  At the end of the
cycle the ventilator will turn off.

If the ventilator is on when the delay button is
pressed, the ventilator runs for 10 minutes at
the current speed then turns off.

During a timed period, the LED above the
Delay Shut Off button is illuminated.

4

5

6

To interrupt a timed period, press Fan Speed
or Off button.

CLEAN FILTER REMINDER – After 40 hours
of operation the clean filter reminder LED above
this button will illuminate indicating that the
filters need to be cleaned. Pressing this button
for 3 seconds resets the 40-hour period and
turns the LED off.

LIGHT On/Dim/Off – This button controls the
halogen lighting. The first press turns the lights
on.  A second press dims the lights.  A third
press turns the lights off.

HEAT LAMP BUTTONS –  The buttons marked
“L” and “R” independently control the left and
right infrared heating lamps, turning the lights
on or off.

®

OFF

FAN

SPEED

DELAY

SHUT OFF

FILTER

LIGHT

HEAT LAMPS

L

R

1

2

3

2

3

4

5

6

1

CONTROL PANEL

Содержание An American Icon PH30ZS

Страница 1: ...mps 1 Infra Red Heat Lamps 2 Filters 3 Step Down Transformer 4 Main Relay Board 5 Input Board 6 Heat Sensor 7 Control Panel 8 Cleaning Instructions 9 Disassembly 10 Stainless Steel Parts 11 Transforme...

Страница 2: ...Wiring Diagram...

Страница 3: ...equivalent tool pry loose the lens cover as shown in Figure 3 Remove the damaged light and replace with a new 12 Volt 20 Watt maximum halogen light made for a G 4 base Follow package directions and d...

Страница 4: ...d produces the same amount of effective heat with lower energy consumption These lamps may not be readily available at local retail outlets The PAR 40 250W heat lamp is readily available at local reta...

Страница 5: ...m and are long lasting To RemoveThe Metal Grease Filters Turn the fan and lights off Allow filters to cool before removal In the following order remove the baffle filters trims and grease troughs To r...

Страница 6: ...ep DownTransformer The step down transformer is a multiple tap 120 v a c step down transformer one tap outputs 12 v a c for regular lights and the other tap outputs 9 6 v a c when the dim light is sel...

Страница 7: ...oard The main relay board is a microproccessor based printed circuit board The relay board has specific relays to activate the components in the hood The relay board reacts to input and commands from...

Страница 8: ...e input board serves as a selector switch the mode is selected on the input board buttons The input board sends the commands to the relay board The relay board and the input board communicate through...

Страница 9: ...corresponding LED will blink 2 If the ventilator is on at any speed the corresponding LED will blink No speed change will occur While the sensor is activated due to excessive heat 1 The ventilator spe...

Страница 10: ...High DELAY SHUT OFF BUTTON Press to turn fan on high for 10 minutes If the ventilator is off when the delay button is pressed the ventilator will turn on to the high speed setting for 10 minutes At th...

Страница 11: ...dishwasher To Clean Hood Surface For general care wipe the outside of the stainless steel with sudsy water or household cleaners such as Fantastic or Formula 409 Rinse well and dry with clean soft cl...

Страница 12: ...ual PAGE 10 The halogen lights and infra red lights are mounted on the light panel To drop light panel and gain access to components 1 Remove 3 screws as illus trated and drop the light panel Disassem...

Страница 13: ...11 Stainless Steel Parts The stainless st5eel parts illustrated below are field replaceable Inside Panel Spacer Light Panel Grease Trough Grease Trough Top Trim Filters Spacer Inside Panel Replaceabl...

Страница 14: ...t panel 2 Remove 4 screws that attach the transformer panel to the sides of the hood see illustration The step down transformer electronic control and wire harness are mounted on the transformer panel...

Страница 15: ...t board is mounted on the inside of the hood To remove the input board 1 Remove light panel 2 Remove 4 number 9 hex head nuts that attach the input board to the hood see illustration Input Board Remov...

Страница 16: ...in accordance with local electrical codes or plumbing codes or improper storage of the appliance Service labor during limited warranty period Travel fees and associated charges incurred when the produ...

Отзывы: