background image

16 

 

CONNECTING TO GAS SUPPLY 

 

WARNING:

 A qualified service technician must connect heater 

to gas supply. Follow the heater specification and all local 

codes. Wrong gas supply may result improper operation, or damage 
on your heater, property or/and personal body.

 

 

WARNING: 

This appliance requires a 3/8-inch UNF (Unified 

National Fine) inlet connection to the pressure regulator. 

 

WARNING: 

Never connect heater to private (non-utility) gas 

wells. This gas is commonly known as wellhead gas. 
 

WARNING: 

Do not over-tighten gas connections. 

 

CAUTION: 

Use only new, black iron or steel pipe. Internally tinned copper tubing may be used in 

certain areas. Check your local codes. Use pipe of 1/2-in. diameter or greater to allow proper gas 

volume to heater. If pipe is too small, undue loss of pressure will occur. 
 

NATURAL GAS MODELS: 
 

CAUTION: 

Check your gas line pressure before connecting heater to gas line. Gas line pressure 

must be no greater than 8 inches of water column. If gas line pressure is higher, damage on 

appliance regulator could occur. 

 

PROPANE MODELS: 
CAUTION: 

Never connect heater directly to the gas supply. This heater requires an external 

regulator (not supplied). Install the external regulator between the heater and gas supply.     
 

CAUTION: 

Avoid damage to regulator. Hold gas regulator with wrench when connecting into gas 

piping and/or fittings. 

 

CAUTION: 

Use pipe joint sealant that is resistant to gas (Propane or Natural Gas). 

 
IMPORTANT:

 Install an equipment shutoff valve in an accessible location where the gas pipe goes 

indoors. The equipment shutoff valve is for turning on or shutting off the gas to the appliance. Apply pipe 
joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant 
in pipe could result in clogged heater valves. The installer must supply an external regulator with nominal 
out

let pressure of 11” water column and sufficient flow rates. Install external regulator with the vent 

pointing down as shown in Figure 9. Pointing the vent down protects it from freezing rain or sleet. If 
flexible gas hose is applied, it should meet the requirements of ANSI/UL569 Standard for Pigtail and 
Flexible Hose Connection for LP-Gas. Improper regulator and/or gas hose assembly may occur damage 
on your heater, property or/and personal body. 
 
 
 

 

 
 

Propane/LP 
supply tank 

External regulator 

Figure 9 - External Regulator with Vent Pointing Down 

Содержание GLDF18T-VF

Страница 1: ...some of our most popular products without requiring any adjustments Our product lines consist of vent free gas wall heaters a direct vent gas wall heater line kerosene and propane forced air heaters...

Страница 2: ...reen must be in place when the appliance is operating and unless other provisions for combustion air are provided the screen shall have an opening s of introduction of combustion air WARNING Keep the...

Страница 3: ...clear and free of debris This will ensure enough air for proper combustion 6 If heater shuts off do not relight until you have provided fresh air from outside If heater keeps shutting off have it ser...

Страница 4: ...ff system The ODS pilot shuts off the heater if there is not enough fresh air PULSE IGNITION SYSTEM This heater is equipped with a battery powered electric pulse igniting system No AC power supply req...

Страница 5: ...priate for heater location The Air Shutter is pre set for Liquid Propane use If using Natural Gas see Air Shutter section of manual Unit successfully tested o Installed by Company ____________________...

Страница 6: ...ompare parts with package contents list and diagram above If any part is missing or damaged do not attempt to assemble install or operate the product Contact customer service for replacement parts Bef...

Страница 7: ...roximately one 1 ounce 30 ml of water for every 1 000 BTUs 0 3 KWs of gas input per hour Unvented room heaters are recommended as supplemental heat a room rather than a primary heat source an entire h...

Страница 8: ...f the aggregate input rating of all appliances installed in that space Rooms connecting directly with the space in which the appliances are installed through openings not furnished with doors are cons...

Страница 9: ...61 000 BTU Hr The space in the prior example is a confined space because the actual BTU hr used is more than the maximum BTU hr the space can support You must provide additional fresh air Your options...

Страница 10: ...quired size of ventilation grills or ducts Ventilation Air from Outdoors Provide extra fresh air by using ventilation grills or ducts You must provide two permanent openings one within 12 inches of th...

Страница 11: ...er creates warm air currents These currents move heat to wall surfaces next to heater Installing heater next to vinyl or cloth wall coverings or operating heater where impurities such as tobacco smoke...

Страница 12: ...tible material other than wood flooring the appliance shall be installed on a metal or wood panel extending the full width and depth of the appliance Installing Damper Clamp Remove all ashes or other...

Страница 13: ...e log set is important as it improves the color and appearance of the flame The Air Door is located on the bottom of the log set heater So you will need to flip it over I recommend laying a cloth down...

Страница 14: ...lide any further Once done you will tighten the screw on the cylinder then seal the air shutter cover again For more information please visit our website www thermablaster com You can contact us at 87...

Страница 15: ...burner holes as this can lead to sooting and an overall drop in the performance of your heater Logs should be placed sequentially from lowest to highest as the numbering indicates There are grooves on...

Страница 16: ...supply This heater requires an external regulator not supplied Install the external regulator between the heater and gas supply CAUTION Avoid damage to regulator Hold gas regulator with wrench when co...

Страница 17: ...1 Disconnect heater with its appliance main gas valve control valve and equipment shutoff valve from gas supply piping system Pressures in excess of 1 2 PSIG will damage heater regulator 2 Cap off ope...

Страница 18: ...WHAT TO DO IF YOU SMELL GAS Open the window or door immediately Do not try to light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supp...

Страница 19: ...is should be done slowly in one motion without stopping between positions Knob will only turn if you have a stable pilot light the heater will now operate normally 5 Adjust the Control Knob to your de...

Страница 20: ...20 Figure 10 Control Panel Figure 11 Pilot System Figure 12 Pilot Blue Flame...

Страница 21: ...bly clean and free of dust and dirt To clean these parts we recommend using compressed air no greater than 30 PSl Your local computer store hardware store or home center may carry compressed air in a...

Страница 22: ...your gas supplier call the fire department IMPORTANT Operating heater where impurities in air exist may create odors Cleaning supplies paint paint remover cigarette smoke cements and glues new carpet...

Страница 23: ...when control knob is released Both control and igniter knobs are not fully pushed down Thermocouples are not heated enough External shutoff valve of gas supply is not fully opened Thermocouple connec...

Страница 24: ...urning vapors from paint hair spray glues etc See IMPORTANT statement Gas leak See Warning Statement Low fuel supply Ventilate room Stop using odor causing products while heater is running Locate and...

Страница 25: ...25 ILLUSTRATED PARTS Model GLDF18T VF...

Страница 26: ...5 Bottom Strengthen strip No 2 12 NG Nozzle 36 Bottom Strengthen strip No 1 13 Air door washer 37 Air door shield 14 Air door rod 38 Sensor bulb bracket 15 Air door 39 Thermostat elbow 16 Burner 40 Th...

Страница 27: ...ce Performed Service Date Please register your product online at www thermablaster com or send in the registration form below to our office at Reecon North America 2515 Liberty Ave Pittsburgh PA 15222...

Отзывы: