Therma-tek MGFCO-1S Скачать руководство пользователя страница 4

INSTALLATION AND SAFETY GUIDELINES 

 

IMPORTANT 

 

Safe and satisfactory operation of your equipment depends on its proper installation. Installation must 

conform to local codes, or in the absence of local codes with the National Fuel Code ANSI Z223.1 (latest 

edition). 

All THERMA-TEK appliances are shipped with a gas pressure regulator packed with the unit.  All units are 

adjusted, tested, and inspected at the factory prior to shipment. 

After uncrating, immediately check the equipment for visible signs of shipping damage.  If such damage has 

occurred, do not refuse shipment, but contact the shipper and file appropriate freight claims. 

 

GENERAL 

 

 

Installation of this equipment should be made by licensed and authorized personnel. 

 

A manual gas shut-off valve must be installed in the gas supply (service) line ahead of the appliance 

and gas pressure regulator installed in the gas stream for safety and ease of future service. 

 

The gas pressure regulator supplied must be installed on the appliance prior to connecting the 

equipment to the gas line.  Failure to install a regulator will void the equipment warranty and result 

in a potentially hazardous condition. 

 

The appliance and its individual shut off valve must be disconnected from the gas supply system 

during any pressure testing of that system in excess of ½ PSI. 

 

The appliance must be isolated from the gas supply system by closing its individual shut off valve 

during any pressure testing of the gas supply piping system at test pressure equal to or less than ½ 

PSI. 

 

Please contact the factory, the factory representative, or a local authorized service company to 

perform maintenance and repairs. 

 

RATING PLATE 

 

Information on this plate includes the model and serial number.  When communicating with the factory 

about a unit or requesting special parts or information, this information is required for proper identification. 

Other information on the plate is the BTU/hr input of the burners, gas pressure in inches WC, and whether 

the unit is orificed for natural or propane gas. 

 

IMPORTANT: 

 The appliance must be connected only to the type of gas identified on the rating plate. 

 

GAS CONVERSION 

 

We recommend that the appliance be ordered from the factory for the type of gas at the installation site.  

When gas conversion is necessary contact the factory for a proper gas conversion kit. 

 

 

 

 

 

 

Содержание MGFCO-1S

Страница 1: ...STOCK POT OWNERS MANUAL AND INSTALLATION INSTRUCTIONS C Made in U S A LISTED UL US UL TJBSP18 TSP18 2 TSP36 TSP18...

Страница 2: ......

Страница 3: ...ANY OTHER APPLIANCE FOR YOUR SAFETY If you smell gas 1 Shut off gas to appliance 2 Extinguish any open flame 3 If odor continues immediately call your gas supplier Consult your local gas supplier for...

Страница 4: ...lator will void the equipment warranty and result in a potentially hazardous condition The appliance and its individual shut off valve must be disconnected from the gas supply system during any pressu...

Страница 5: ...adequate air supply Means must be provided for any commercial heavy duty cooking appliance to exhaust combustion wastes to the outside of the building Air movement should be checked during installati...

Страница 6: ...ly and blow them out with compressed air to clear any dirt particles threading chips or any other foreign matter before installing a service line Those particles will clog orifices when gas pressure i...

Страница 7: ...s and checking for leaks do not stand with you face close to the combustion chamber The pilots can be accessed from the top of the unit through the top grate or wok top Make sure main burner valve is...

Страница 8: ...terials soak in hot water to loosen the material then use a nylon or wood scraper to loosen debris Never use a spatula knife or any other metal tool to scrape stainless steel These tools will scratch...

Страница 9: ...horized service agency in your area contact your local dealer He will have a listing of authorized dealers in your area or on the web www therma tek com We want you to remain a satisfied customer If a...

Страница 10: ...codes and in accordance with the Therma Tek installation manuals Therma Tek products are warranted to the original purchaser to be free from defects in material and workmanship under normal use and s...

Страница 11: ...THIS PAGE LEFT INTENTIONALLY BLANK...

Страница 12: ...Rotary Drive West Hazleton PA 18202 www therma tek com info therma tek com 877 THERTEK 843 7835 Tel 570 455 3000 Fax 570 455 9491 A Division of TEKMA Corporation 7700 NW 37th Avenue Miami Florida 331...

Отзывы: