Ultra-Aire XT105H, XT155H, and XT205H Installer’s & Owner’s Manual

Unit:

4032240 XT105H

4031070 XT155H

4031560 XT205H

Blower: 

(Tested with duct collars on)

257 CFM @ 0.0" WG 
206 CFM @ 0.2" WG 
146 CFM @ 0.4" WG

391 CFM @ 0.0" WG 
363 CFM @ 0.2" WG 
337 CFM @ 0.4" WG

526 CFM @ 0.0" WG 
495 CFM @ 0.2" WG 
458 CFM @ 0.4" WG

Power:

530 Watts @ 80°F and 60% RH

920 Watts @ 80°F and 60% RH

1525 Watts @ 80°F and 60% RH

Supply voltage:

110-120 VAC - 1 Phase - 60 Hz.

110-120 VAC - 1 Phase - 60 Hz.

110-120 VAC - 1 Phase - 60 Hz.

Current Draw:

4.9 Amps

8.0 Amps

13.2 Amps

Energy Factor:

4.2

3.5

2.7

Operating Temp:

56°F Min - 95°F Max

56°F Min - 95°F Max

56°F Min - 95°F Max

Sized For:

2500 Square Foot Typical

3500 Square Foot Typical

5000 Square Foot Typical

Minimum Performance @ 80°F and 60% RH:

Water Removal: 

Efficiency:

105 Pints/Day 
8.8 Pints/kWh

155 Pints/Day 
7.3 Pints/kWh

205 Pints/Day 
5.7 Pints/kWh

Duct Connections:

 

Inlet:  

10" Round Duct Collar 

 

 

6" Round Duct Collar 

 

Outlet:  

10" Oval Duct Collar

 

Inlet:  

10" Round Duct Collar 

 

 

6" Round Duct Collar 

 

Outlet:  

10" Oval Duct Collar

 

Inlet:  

10" Round Duct Collar 

 

 

6" Round Duct Collar 

 

Outlet:  

10" Oval Duct Collar

Air Filter:

MERV-11 Size: 16" x 20" x 2"

MERV-11 Size: 16" x 20" x 2"

MERV-11 Size: 16" x 20" x 2"

Power Cord:

10' 16/3 SJT w/ 5-15P Plug

10' 16/3 SJT w/ 5-15P Plug

10' 16/3 SJT w/ 5-20P Plug  

*This unit requires a dedicated 20A circuit

Drain Connection:

3/4 NPT

3/4 NPT

3/4 NPT

Dimensions:

 

Width: 

Height: 

Length: 
Weight:

Unit

  

Shipping

 

20.25" 

24" 

21.75" 

28.25" 

38" 
140 lbs 

160 lbs

Unit

  

Shipping

 

20.25" 

24" 

21.75" 

28.25" 

38" 
140 lbs 

160 lbs

Unit

  

Shipping

 

20.25" 

24" 

21.75" 

28.25" 

38" 
150 lbs 

170 lbs

  42"

  42"

  42"

Содержание Ultra Aire XT105H

Страница 1: ...outdoor air may be ducted to the unit via a six inch round duct This provides fresh air to dilute pollutants and replenish oxygen content in the building The amount of fresh air ventilation can be reg...

Страница 2: ...2 Ultra Aire XT105H XT155H and XT205H Installer s Owner s Manual...

Страница 3: ...3 Ultra Aire XT105H XT155H and XT205H Installer s Owner s Manual...

Страница 4: ...are Foot Typical Minimum Performance 80 F and 60 RH Water Removal Efficiency 105 Pints Day 8 8 Pints kWh 155 Pints Day 7 3 Pints kWh 205 Pints Day 5 7 Pints kWh Duct Connections Inlet 10 Round Duct Co...

Страница 5: ...FOR HVAC INSTALLER ONLY 5 Ultra Aire XT105H XT155H and XT205H Installer s Owner s Manual...

Страница 6: ...6 Ultra Aire XT105H XT155H and XT205H Installer s Owner s Manual...

Страница 7: ...Ultra Aire Dehumidifier 7 Ultra Aire XT105H XT155H and XT205H Installer s Owner s Manual...

Страница 8: ...T155H and XT205H Installer s Owner s Manual P N 4028539 with remote P N 4028407 Ultra Aire Dehumidifier RED YELLOW BLUE GREEN or BROWN WHITE Internal Connections OPTIONAL DAMPER 24 VAC DMP COMP FAN Ul...

Страница 9: ...y the transformer Dehumidifier on Connect yellow and blue wires Fan only on Connect yellow and green or brown wires Accessory power 24volt AC power supply available for HVAC accessories between yellow...

Страница 10: ...10 Ultra Aire XT105H XT155H and XT205H Installer s Owner s Manual DEH 3000 DEH 3000R DEH 3000 DEH 3000R Part No 4028539 Part No 4028407...

Страница 11: ...peration and no further oiling is required 6 4 Optional Fresh Air Return Check and clean the screen on the outdoor fresh air return seasonally The screen may become plugged during the seasons when the...

Страница 12: ...ls from the main unit together only the impeller fan should run Disconnect the wires 3 Connect the yellow and blue pigtails from the main unit together the compressor and impeller fan should run 4 If...

Страница 13: ...a very corrosive acid and water These contaminants must be carefully removed otherwise even small residues will attack replacement compressor motors and cause failures The following procedure is effe...

Страница 14: ...ction tube between the accumulator and the compressor It will automatically shut the compressor off if the low side refrigerant temperature drops due to excessive frost formation on the evaporator coi...

Страница 15: ...ONTROL WIRING Electric Schematics of the Ultra Aire XT N O WHT 4 UNIT E BOX 1 59 1413 WHT 4 BLK 1 8 2 3 2 2 2 3 7 5 COM COM 115V 24V WHT 6 BLU 7 YEL 6 RED 1 GRN 5 RED 6 5 WHT 6 BLU 2 BLU 2 BLK 1 BRN 3...

Страница 16: ...029714 1 XT155 Compressor Overload NOT SHOWN 4031574 1 XT205 Compressor Overload LOCATED IN COMPRESSOR CAP Item Part No Qty Description 8 4032196 1 XT105 Impeller 8 4026657 1 XT155 Impeller 8 4031089...

Страница 17: ...Condensate Pump Kit External 4023672 1 Duct Damper 6 Diameter Electrically Actuated 4025560 1 Switch Black SPDT On Off 4024369 1 Merv 11 Standard Filter 20 x 16 x 2 4032221 1 Filter Box Needed when M...

Страница 18: ...is shut release the door latch Collar Install Remove the 2 round ducts oval duct seal and small bag of mounting hardware from inside the rectangle opening Adhere seal onto the back of oval duct and mo...

Страница 19: ...ts related to changes to a Product or Component that may be required by any codes laws or regulations that may become effective after initial purchase of the Product by Customer Customer Responsibilit...

Страница 20: ......

Отзывы: