background image

 [email protected]

 

            TS-601 01/12

n

   Free-standing  dehumidification   

for your home.

n   

Includes installation, operating 
and safety instructions, warranty 
information and all ancillary 
products.

Read and save these instructions.

For small usage:

420l Lien Rd., Madison, WI 53704 

 TOLL-FREE 1-800-533-7533 

 www.thermastor.com

INSTALLER’S & OWNER’S MANUAL

P/N 4029700  •  Serial No.________________________ Install Date:___________ 
Sold by:

Содержание Santa-Fe Classic

Страница 1: ...operating and safety instructions warranty information and all ancillary products n Read and save these instructions For small usage 420l Lien Rd Madison WI 53704 TOLL FREE 1 800 533 7533 www thermast...

Страница 2: ...to remove corrugated shipping cardboard from top of unit Specifications Part Number 4029700 Blower 275 CFM 0 0 WG Power 720 watts 80 F and 60 RH Supply Voltage 115 volt 1 phase 60 Hz Current Draw 6 4...

Страница 3: ...he room in which it s located An adequate air flow path must exist between the two rooms for this method to work well An additional humidity control may need to be mounted in the humid area and wired...

Страница 4: ...t is cooled and condensed by giving up its heat to the air that is about to be discharged from the unit The refrigerant liquid then passes through a filter drier and capillary tubing which cause the r...

Страница 5: ...yellow wires from compressor terminals R S Using an ohmmeter check continuity between the points listed below 4 Compressor terminals C and S No continuity indicates an open start winding The compress...

Страница 6: ...ith 35 to 50 PSIG refrigerant vapor charge Leave the vapor charge in the system from at least 5 minutes before removing it Repeat the vapor charge wait remove sequence twice more and then charge the s...

Страница 7: ...6 Wiring Diagram SANTA FE CLASSIC WIRING DIAGRAM 7 Santa Fe Classic Installer s Owner s Manual Figure 2 Electrical Schematic of the Santa Fe Classic Dehumidifier...

Страница 8: ...4025741 1 Defrost Thermostat 4021648 1 Defrost Control Mounting Clip 12 4028225 1 Evaporator Coil 13 4029510 1 Filter Drier 14 4021626 1 Hose Drain 56 ID x 8 15 4021469 1 Humidity Controller 16 402149...

Страница 9: ...Insert a romex connector or conduit connector into the hole in the cabinet that is left after the dehumidistat is removed Pass the cable to be used to connect to the remote dehumidistat through the c...

Страница 10: ...are located near the bottom and on the same side of the unit as the drain hose STEP 5 Example of hose cut at a 45 angle The angle prevents the hose from sealing tight against the bottom of the pump re...

Страница 11: ...ach the inlet to the guides 4 Replace the filters in the unit Exhaust Collar Mounting Instructions 5 The six inch opening may be used as a fresh air inlet from outside 6 Remove the exhaust collar from...

Страница 12: ...and 2 screws are not used on the Santa Fe Classic Loosen these 2 screws enough to slide the silencer under the screw heads Insert 1 screw from the enclosed parts and tighten Santa Fe Classic Muffler...

Страница 13: ...er s Owner s Manual Instructions To prevent damaging the foam filter place it grid side up on top of the pleated filter and slide them both into the filter slot Foam filter with plastic grid up Pleate...

Страница 14: ...ent that may be required by any codes laws or regulations that may become effective after initial purchase of the Product by Customer Customer Responsibilities As a further condition to obtaining warr...

Страница 15: ...uced or transmitted in any form or by any means electronic or mechanical for any purpose without the express written permission of Therma Stor LLC 2008 Therma Stor LLC All rights reserved 4201 Lien Rd...

Отзывы: