Therma-Stor Phoenix Mini-Guardian Скачать руководство пользователя страница 5

5

www.thermastor.com • [email protected]

Toll-Free 1-800-533-7533

CAUTION: Do not remove the top to access the filters with 
the unit on. Removing the top and filters while running can: 
(A) expose potentially fatal high voltage electrical parts, and 
(B) expose the dangerous rotating impeller fan.

2.8 Hour Meter

A digital hour meter is located near the power/speed 
control on the unit front. It measures the cumulative time 
that the unit is turned on to tenths of an hour. It stores its 
total when the unit is unplugged. The previous total will be 
displayed when the unit is next turned on. 
It resets to zero after 99,999.9 hours of operation.

3 Maintenance

3.1 Air Filters

The standard Phoenix Mini-Guardian HEPA System is 
equipped with three filters that progressively filter out 
smaller particles. An optional activated carbon/potassium 
permanganate filter can be used, giving a fourth stage 
of filter media (see Section 3.A). These filters must be 
checked regularly. Operating the unit with dirty filters will 
reduce the airflow, but will do no harm to the unit. The unit 
can be run indefinitely with dirty filters.
The three standard filters used are listed below (as 
installed in the unit from top to bottom):
A.  Polyester media pad pre-filter. Actual size 5-3/4” x 

5-3/4” x ” thick. The white side faces up. This filter 
should be replaced when the airflow is reduced, it is 
visibly dirty or when it is contaminated by a previous 
job.

B.  25 to 30% efficient (per ASHRAE 52.-992), MERV-7,  

pleated fabric filter. Actual size is 5-3/4” x 5-3/4”  
x -3/4”. This filter should be changed when airflow is 
reduced or it is contaminated by a previous job.

C.  99.97% DOP efficient HEPA filter. Actual size is  

3-7/8” OD x 24” x 8-7/8” ID. This filter should be 
changed when airflow is reduced or it is contaminated 
by a previous job.

3.1A Activated Carbon/Potassium Permanganate Filters

Optional gas phase filters are available from Therma-
Stor. They use a blend of activated carbon and potassium 
permanganate. This blend removes the vast majority of 
contaminants encountered in most filtering applications. 
The activated carbon removes the heavier volatile organics 
while the potassium permanganate removes lower 
molecular weight contaminants. This is well suited to the 
smoke odors present after fire damage.
The life of the media blend depends upon both the hours 
used and the contamination level. Another advantage 
of the blended media versus activated carbon only is 

that part of the blend changes color as it loads up with 
contaminants. It starts out black, then turns pink, then 
brown, and finally white. It is best changed when it passes 
the brown stage and begins to turn white. It has lost most 
of its effectiveness at that point. When these filters are 
installed, the pad filter does not need to be installed above 
them. This allows the operator to check the media color 
through the top grill of the unit without removing the top.
The filter is the same size as the pleated fabric filter. 
Install it above the pleated fabric filter. The pleated fabric 
filter catches carbon dust that comes off the carbon filter 
before it reaches the HEPA filter.
The refillable carbon filter is metal-framed and can be 
refilled with carbon blend media purchased in 5-gallon 
buckets. The amount of carbon blend media loaded into 
the filter can be adjusted to the particular amount of gas/ 
odor removal required.

3.2 Checking Airflow

The airflow is checked using a Phoenix Kestrel 3000 
airflow meter placed on the designated area on the top of 
the unit.

To check airflow:

·  Remove any inlet ducting, but leave the top and all 

filters in place.

·  Turn the unit on high. The airflow meter will indicate an 

air speed. Please set the air meter to read FPM (refer to 
the meter instructions to set the mode). To determine 
CFM see the chart below:

Figure 7: Checking airflow

Kestrel 3000 FPM

700  650  600  550  500  450  400  350  300  250  200  150
400  371  343  320  286  263  235  208  182  153  120  87

CFM

Содержание Phoenix Mini-Guardian

Страница 1: ...e on the intake grill makes it possible to take air flow measurements with the Phoenix Kestrel 3000 Multi Meter The Mini Guardian HEPA System s 3 stage filter design with true HEPA filtration will remove virtually all hazardous particles from the air and an optional fourth stage filter of activated carbon and potassium permanganate will absorb a wide range of odors and gases The unique 24 canister...

Страница 2: ...ion and maintenance instructions carefully before using this unit Proper adherence to these instructions is essential to obtain maximum benefit from your Phoenix Mini Guardian HEPA System 1 Specifications Part No 4024774 Power 110 120 Vac 1 96 amps 215 watts Blower Up to 415 CFM delivered air flow w 3 stage filter operation Filters 1 stage 1 Spun Polyester 16 x 16 2 stage 2 Pleated Media 16 x 16 3...

Страница 3: ...sembly is secured against the cabinet surface and all space between parts is eliminated 2 2 Transporting the Phoenix The Phoenix Mini Guardian HEPA System should be upright when transported by vehicle It may be tipped on to its back for loading and moving by hand or for use on location 2 3 Location Note the following precautions when locating the Phoenix Mini Guardian HEPA System It is designed to...

Страница 4: ...s would result in up to 400 CFM being exhausted on high speed and an equal amount of fresh air being drawn in CAUTION Exhausting too much air from a space with open combustion devices e g furnace fireplace or water heater can cause those devices to backdraft This can contaminate the space with potentially fatal gases In such cases the Phoenix Mini Guardian HEPA System must be used in one of the fo...

Страница 5: ...l gas phase filters are available from Therma Stor They use a blend of activated carbon and potassium permanganate This blend removes the vast majority of contaminants encountered in most filtering applications The activated carbon removes the heavier volatile organics while the potassium permanganate removes lower molecular weight contaminants This is well suited to the smoke odors present after ...

Страница 6: ... be changed Change the pleated fabric filter middle second It is the second least expensive filter Recheck the airflow If acceptable the HEPA filter does not need changing If the airflow is still too low the HEPA filter must be changed To remove the HEPA filter follow these steps 1 Loosen the two 3 8 thumbscrews that secure the HEPA filter 2 Push down on the filter hold down bar and out on the bac...

Страница 7: ...ealth hazard that could result in death serious bodily injury and or property damage Only qualified service people should service this unit 4 1 Warranty A warranty certificate has been enclosed with this unit Read it before any repair is initiated If a warranty repair is required call the factory first at 1 800 533 7533 for warranty claim authorization and technical assistance 4 2 Impeller Fan Rep...

Страница 8: ...ese base supports 8 Using a pliers twist the tabs of the base supports to align with the slots Remove only one of the base supports see below Spread the base apart slightly to remove the impeller fan 9 Remove the four 4 mm machine screws and lock washers securing the impeller fan 10 Reverse this procedure to reassemble with the new impeller fan ...

Страница 9: ...oot 12 4026093 1 Handle Assembly 13 4021597 1 Hour Meter 14 4021700 1 Pocket Handle 15 4024692 1 Run Capacitor 20 mfd 370 VAC 16 4024070 2 Outlet Cover Side 17 4024078 1 Outlet Duct Collar 18 4024822 1 Outlet Cover Guard Rear 19 4024827 6 Thumb Screw 1 4 20 4024828 2 Thumb Screw 3 8 21 4024066 2 Wheel 5 Plastic 22 4024821 2 Wheel Center Cap Optional Parts 4021950 Ground Fault Interrupter 4024879 A...

Страница 10: ...10 www thermastor com sales thermastor com Toll Free 1 800 533 7533 This page intentionally left blank ...

Страница 11: ...stallation accident acts of nature or any other cause beyond Therma Stor Products reasonable control Limitations and Exclusions If any Mini Guardian HEPA System part is repaired or replaced the new part shall be warranted for only the remainder of the original warranty period applicable thereto but all warranty periods will be extended by the period of time if any that the Mini Guardian HEPA Syste...

Отзывы: