background image

3

USEPHOENIX.COM  

|

  800-533-7533

3.2 Electrical Requirements

The Phoenix Focus II can be plugged directly into any 

standard wall receptacle. Without ducting, the Phoenix 

Focus II will draw 1.1 amps at 110-120 VAC. Ducting will 

reduce amp draw. Up to 10 Phoenix Focus IIs can be daisy 

chained on a standard 15 amp branch circuit.

3.3 Focus Corners

The Phoenix Focus II is designed with four focus corners to 

optimize drying over a wide surface area staring directly at 

the front of the device.

3.4 Resettable Circuit Breaker

The 12 Amp thermal circuit breaker protects the unit and 

devices connected receptacle. In case of a fault, the breaker 

can be reset at the Phoenix Focus II control panel. 
Use of multiple fans and any other connected devices must 

be in accordance with the National Electric Code and any 

additional codes or laws required by your local government.

IMPORTANT: Total amperage of the Phoenix Focus II plus all 

devices plugged into its convenience receptacle is limited 

by the onboard circuit breaker. Excessive current will cause 

the circuit breaker to trip. This may occur instantly or after 

a period of time depending on the operating conditions. 

IMPORTANT: When the Phoenix Focus II is plugged into 

a standard “powered” wall outlet the Phoenix Focus II is 

electrically “HOT” and AC voltage is present.

4 Maintenance

WARNING: Disconnect the unit from power before servicing 

or cleaning. Replace all safety grills after servicing or 

cleaning.

4.1 Power Cord 

Visually inspect cord and plug head before use. If there are 
signs of damage or excessive wear, discontinue use until the 

unit has been serviced.

4.2 Cleaning

The housing is made of durable and washable 

polypropylene. When cleaning, the use of solvents is NOT 

recommended.
When washing inside the unit, disconnect the unit from its 

power source. Protect the switch, receptacle and circuit 

breaker from water intrusion. Do not spray water or cleaning 

solution at motor. If motor does get wet, allow motor to dry 

completely before restarting. If fan is to be washed and not 

used within 24 hours, allow fan to drip dry for 10 minutes 

and then run for 5 minutes before storing.

IMPORTANT: Do NOT remove impeller blade from motor 

assembly. Doing so can cause blade to become imbalanced 

upon re-assembly.

4.3 Service

CAUTION: Servicing the Phoenix Focus II with its high voltage 

circuitry presents a health hazard that could result in death, 

serious bodily injury, and/or property damage. Disconnect 

the appliance from the power supply before servicing. Only 

qualified service people should service this unit. 

CAUTION: If the supply cord or circuit breaker become 

damaged, they must be replaced by the manufacturer, its 

service agent or similarly qualified person in order to avoid a 

hazard.