3
USEPHOENIX.COM
|
800-533-7533
3.2 Electrical Requirements
The Phoenix Focus II can be plugged directly into any
standard wall receptacle. Without ducting, the Phoenix
Focus II will draw 1.1 amps at 110-120 VAC. Ducting will
reduce amp draw. Up to 10 Phoenix Focus IIs can be daisy
chained on a standard 15 amp branch circuit.
3.3 Focus Corners
The Phoenix Focus II is designed with four focus corners to
optimize drying over a wide surface area staring directly at
the front of the device.
3.4 Resettable Circuit Breaker
The 12 Amp thermal circuit breaker protects the unit and
devices connected receptacle. In case of a fault, the breaker
can be reset at the Phoenix Focus II control panel.
Use of multiple fans and any other connected devices must
be in accordance with the National Electric Code and any
additional codes or laws required by your local government.
IMPORTANT: Total amperage of the Phoenix Focus II plus all
devices plugged into its convenience receptacle is limited
by the onboard circuit breaker. Excessive current will cause
the circuit breaker to trip. This may occur instantly or after
a period of time depending on the operating conditions.
IMPORTANT: When the Phoenix Focus II is plugged into
a standard “powered” wall outlet the Phoenix Focus II is
electrically “HOT” and AC voltage is present.
4 Maintenance
WARNING: Disconnect the unit from power before servicing
or cleaning. Replace all safety grills after servicing or
cleaning.
4.1 Power Cord
Visually inspect cord and plug head before use. If there are
signs of damage or excessive wear, discontinue use until the
unit has been serviced.
4.2 Cleaning
The housing is made of durable and washable
polypropylene. When cleaning, the use of solvents is NOT
recommended.
When washing inside the unit, disconnect the unit from its
power source. Protect the switch, receptacle and circuit
breaker from water intrusion. Do not spray water or cleaning
solution at motor. If motor does get wet, allow motor to dry
completely before restarting. If fan is to be washed and not
used within 24 hours, allow fan to drip dry for 10 minutes
and then run for 5 minutes before storing.
IMPORTANT: Do NOT remove impeller blade from motor
assembly. Doing so can cause blade to become imbalanced
upon re-assembly.
4.3 Service
CAUTION: Servicing the Phoenix Focus II with its high voltage
circuitry presents a health hazard that could result in death,
serious bodily injury, and/or property damage. Disconnect
the appliance from the power supply before servicing. Only
qualified service people should service this unit.
CAUTION: If the supply cord or circuit breaker become
damaged, they must be replaced by the manufacturer, its
service agent or similarly qualified person in order to avoid a
hazard.