1. Specifications

Part Number:

       4029410

Power:

 

     1.8 full load amps, 120 V / 60Hz

Blower:

 

     950 CFM

Temperature 
Set Point Range:

   40ºF to 180ºF

Filter Box  
(Option):

 

     Filter Size: 16” X 16” X 2”

Hydronic 
Connections:

       3/4” ISO 7241 Series B couplings

Duct

 

      Inlet: 16” Flex-Duct

Connections:

        Supply: 14” Lay Flat-Duct

 

 

Warranty:

 

      1 Year Parts and Labor

Dimensions:

 

 

    Unit   

Shipping 

Width   

    20.25” 

24” 

Height   

    40”   

45.25”

Depth   

    21.375” 

25.5”

Weight   

    85 lb  

110 lb 

2. Operation

2.1 Transporting

The Phoenix Aquadry TX 80 may be transported and 
operated upright or on its back. The unit features a high-
impact plastic skid plate which protects the unit while 
navigating obstacles such as curbs, stairways, and while 
loading into vehicles.

2.2 Electrical Requirements

The Phoenix Aquadry TX 80 requires 120VAC and features 
a standard 120VAC inlet receptacle with ground. When 

properly connected to a grounded outlet, it provides a 
ground connection through the user-supplied cord in order 

protect the operator from electric shock. Ensure that the 

supply cord used is a 2-conductor with ground and that it 
has no nicks or cuts in the insulation. The electrical inlet 

is designed to accept a NEMA 5-15R (receptacle - 15 amp, 

2 pole + ground).

2.3 Power Switch and Thermostat

Master POWER Switch: The master power switch located 

on the side of the Phoenix Aquadry TX 80 can be used to 

turn the unit ON, OFF.

When set to ON, the Phoenix Aquadry TX 80 will energize 

the blower. 

Temperature set point can be set by 

using a flat-bladed screwdriver. The thermostat will 
control only the blower motor - not the glycol fluid  - 
so the unit may be hot even when the blower is not 
energized. 

The blower will cycle on and off as needed to 

maintain the selected temperature.  

2.4 Glycol Line Connections

Hydronic (hot water/propylene glycol) connections are 
made using 3/4 inch couplings that comply with the ISO 
7241 Series B standard. These couplers minimize the 

fluid loss on disconnection – but there is a small amount 

lost (~1 tablespoon/16cc).  The Phoenix Aquadry TX 80 

has been designed to direct this loss away from the fan 
inlet.

Ensure that the hydronic pump is off before attempting 

connection of the hydronic couplers.

Heat transfer fluid temperatures can approach 200°F 

(93C). Use gloves when handling hot couplers and working 

around the unit’s hot surfaces.

2.4 Ducting

The Phoenix Aquadry TX 80 can be ducted at the 
inlet, the outlet or both. The Phoenix Aquadry TX 80 
comes equipped with a snap ring on the outlet that 

accommodates 14” lay-flat duct. By adding the optional 
ductable filter box assembly, 16” flex duct can be used 
on the inlet. When ducting the TX 80, care must be taken 

to ensure airflow is not choked off due to kinks or sharp 
bends in the duct.

  

3 Maintenance

3.1 Cleaning

Coils should be checked periodically to ensure they are 

free of dirt and debris.  Remove debris from coil with 
compressed air (preferred method). If coils become 

contaminated, they can be washed down with water and 
blown dry with compressed air.  

If the Phoenix Aquadry TX 80 is operated in dirty 

environments, the optional air filter kit should be installed 
on the intake of the machine.  

Содержание Phoenix Aquadry TX 80

Страница 1: ...ven heat distribution throughout the structure Owner s Manual Phoenix Aquadry TX 80 Installation Operation Service Instructions Read and Save These Instructions www UsePhoenix com sales UsePhoenix com...

Страница 2: ...t operating unattended Always unplug unit when not in use DO NOT OPERATE with damaged cord inlet receptacle or after unit malfunctions has been dropped or damaged in any manner Return to authorized se...

Страница 3: ...mperature set point can be set by using a flat bladed screwdriver The thermostat will control only the blower motor not the glycol fluid so the unit may be hot even when the blower is not energized Th...

Страница 4: ...ower not running 1 Unit unplugged no power to inlet receptacle 2 Power switch not working or thermostat not calling for heat 3 Wiring fault inside device 4 Defective blower motor or capacitor Blower r...

Страница 5: ...CLAMP 4029411 4 3 DUST CAP 4029781 1 4 DUST PLUG 4029782 1 5 COUPLING MALE 3 4 x3 4 FNPT 4029783 1 6 COUPLING FEMALE 3 4 x3 4 NPT 4029784 1 7 THERMOSTAT 4030411 1 8 NUT JAM 1 25 12 UNF 2B ZP 4029418 2...

Страница 6: ...accident acts of nature or any other cause beyond Therma Stor LLC reasonable control Limitations and Exclusions If any Phoenix Aquadry TX 80 part is repaired or replaced the new part shall be warrante...

Страница 7: ......

Страница 8: ......

Страница 9: ......

Страница 10: ......

Страница 11: ......

Страница 12: ......

Страница 13: ......

Отзывы: