1 Appropriate Use

The measuring device must only be operated within the 
products specifications.
The measuring device must only be used under the 
conditions and for the purposes for which it was designed.
Modification to this device will void the warranty and 
may compromise the accuracy and safe operation of this 
device.

Before Initial Operation:

•  Open the battery case on the back of the instrument.
•  Pull out the insulating tape from the top of one of the 

batteries.

•  The Humiport is ready to use.

2 Humiport 10/20

The hand-held devices for measuring temperature and 
humidity have the following features:

•  Large display with backlighting
•  Three-way thumb wheel operation
•  Rugged and easy to handle enclosure
•  High accuracy

The Humiport 10 is equipped with a fixed probe whereas 
the Humiport 20 consists of a flexible probe connected to 
the main body through a cable.

3 The Humiport 10/20 Display

Table of Contents

Introduction

 ................................................................1 

1.   Appropriate Use ....................................................2
2.   Display .................................................................2
3.   Operation .............................................................2
 

3.1 Three Positions of the Thumb Wheel .................2

4.   Upper Menu ..........................................................3
5.   Lower Menu ..........................................................3
 

5.1 Single-Point Calibrations of ..............................3 
Temperature and RH

6.   Measuring the Humidity Ratio.................................3
7.   Replacing the Battery ............................................3
8.   Maintenance and Adjustment .................................3
9.   Specifications .......................................................4
10. Warranty/Sensor Repair .........................................5

Serial No. ___________________________

Purchase Date ______/______/_____

Dealer’s Name ___________________________________

Read the operation and maintenance instructions carefully 
before using this the Humiport 10/20.
Do not measure near live electrical components.
Avoid using in temperature conditions outside of that 
recommended (overheating can lead to their destruction)
Calibration should only be adjusted when used with a 
recommended calibration source or known standard.
Allow approximately 2 minutes for stabilization when taking 
measurements in dramatically different environments.

IMPORTANT WARRANTY INFORMATION BELOW:

The plastic protection cap must be placed on the sensing 
head whenever the meter is not in use. Without this 
protection the sensing elements can be mechanically 
damaged or chemically contaminated.  Meter failures due 
to damage or contamination of the sensing elements are 
not covered under warranty.

Upper menu with 
date and clock

Lower menu for configuration 
and adjustment

Hold  MAX  MIN  AVG

Sensor 1

88:88

-1.8.8.8.8

Temperature reading

Temperature Display 
Units (°C, °F)

Humidity reading

Display value g/m

3

,%rH, 

dp°F, °C,g/Kg.gr/lb (gpp)

%rH   °F °C

Sensor 1

-1.8.8.8.8

g/m

3

%rHdp°F °C

Unit1 Unit2 TimeDate
Auto Off CAL 12LH

g/kg   g/lb               Alt(ft)

Содержание Humiport 10

Страница 1: ...r head or near the floor Each Humiport Meter offers a large display for easy reading and all of the important restoration information including temperature either F or C relative humidity dew point F...

Страница 2: ...the Humidity Ratio 3 7 Replacing the Battery 3 8 Maintenance and Adjustment 3 9 Specifications 4 10 Warranty Sensor Repair 5 Serial No ___________________________ Purchase Date ______ ______ _____ Dea...

Страница 3: ...ivate selection with or interrupt with t or by not pressing the wheel for 20 seconds 5 Upper Menu The following functions can be selected in the upper menu HOLD MAX MIN AVG Once the upper menu is acti...

Страница 4: ...only be performed by a reputable calibration laboratory The original factory calibration can be reset by adjusting the offset for CA2L and CAL2H to 0 0 RH 00 0 rH 80 0 rH SENSOR 1 20 0 F C SENSOR 2 80...

Страница 5: ...VG Sensor 1 88 88 1 8 8 8 8 rH F C Sensor 1 1 8 8 8 8 g m3 rHdp F C Unit1 Unit2 TimeDate Auto Off CAL 12LH g kg g lb Alt ft 9 Maintenance And Adjustments Clean the device with a damp cloth as necessar...

Страница 6: ...t If you believe your Humiport has a defect in workman ship contact Phoenix Restoration to arrange for a replacement unit If you have damaged your Humiport and you feel it may need repair or replaceme...

Страница 7: ...enix if the unit is found to be defective according to the warranty it will be repaired or replaced at no charge If the product is found not to be covered by the warranty the customer will be offered...

Отзывы: