background image

8

USEPHOENIX.COM

1.800.533.7533

Specifications subject to change without notice.

8 Service Parts

Item 

Description 

Qty 

Part No.

1  

Top Cover 

1  

4031258

2  

Filter, 12” x 12” x 1”  

1  

4026315

3  

Impeller, Air Mover  

1  

4034477

Evaporator Coil  

1  

4031253

5  

Condenser Coil  

1  

4031254

6  

Condensate Pump  

1  

4034496

7  

Capacitor, Compressor, 35 μF   1  

4033032-03

8  

Compressor  

1  

4029567

Thermistor Probe 

1  

4034716-02

10  

Capacitor, Impeller, 6.0 μF  

1  

4033031-03

11  

Hex Bolts,  1/4”–20 x 1.50”   6  

1154013

12  

Handle Bar 

1  

4031267

13 

Handle Grip 

4031268

14  

Wheel, 12”, Gray 

2  

4026304

15  

Cotter Pin  

2  

1284404

16  

Hub Cap, Wheel, Gray 

2  

4027137

17 

Handle Knob 

4032327

18  

Control Board  

1  

4034457

19  

Power Cord  

1  

4032297

Items listed are not shown

Description  

Qty  

Part No.

Hose (1/4” ID x 33’ long)  

1  

4024916

Coupling Body, 1/4” Tube  

1  

4024910

Coupling Insert, 1/4” Tube  

1  

4027277

Exhaust Grill  

1  

4026308

Wire Duct Collar  

1  

4026309

Handle Grip Screws 

4032414

Handle Attachment Bolt 

1154006

To Add Lanyard (not originally included with the unit)
Handle Knob, Lanyard 

4033372

Handle to Base Screws 

4033371

1

2

3

4

5

6

7

8

9

10

11

12

13

14 15

16

17

18

19

Содержание 4032350

Страница 1: ...fficiency front cord and hose storage a ductable outlet a pleated media filter and a rotating handle for easy transport and storage The Phoenix R125 LGR Dehumidifier LGR Performance in a 79 lb 20 x 17...

Страница 2: ...knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play...

Страница 3: ...the low side refrigerant temperature drops due to exces sive frost formation on the evaporator coil and below the temperature set point the thermistor activates the solid state control and defrost lig...

Страница 4: ...water 4 If the unit will be exposed to freezing temperatures after purging pull back the filter and pour 1 cup 8oz of a propylene glycol based anti freeze through the heat exchanger It will flow down...

Страница 5: ...d 5 Defective compressor 6 Defective control board Air mover does not run Compressor runs briefly but cycles on and off 1 Loose connection in blower circuit 2 Obstruction prevents impeller rotation 3...

Страница 6: ...e wiring bolts and housing in the reverse order 6 Options Accessories 4026315 Air Filter Pleated 12 x 12 x 1 MERV 8 4025568 Air Filter Pleated 12 x 12 x 1 MERV 11 4024935 Lay Flat Duct 10 Round x 250...

Страница 7: ...7 BLK 3 GRN BLU 8 BLK 4 BLK 11 YEL YEL BLU YEL YEL 10 RED 9 WHT 7 BLK GRY WHT 6 CONTROL BOARD RUN CAP FAN MOTOR PUMP SAFETY NO NC FLOAT WHT PUMP FAN LEVEL SWITCH THERMISTOR 1 LINE 2 NEUT 3 COMP RUN C...

Страница 8: ...1 50 6 1154013 12 Handle Bar 1 4031267 13 Handle Grip 1 4031268 14 Wheel 12 Gray 2 4026304 15 Cotter Pin 2 1284404 16 Hub Cap Wheel Gray 2 4027137 17 Handle Knob 2 4032327 18 Control Board 1 4034457...

Страница 9: ...efect malfunction etc resulting from misuse abuse lack of normal care corrosion freezing tampering modification unauthorized or improper repair or installation accident acts of nature or any other cau...

Отзывы: