Therma-Stor 4025081 Скачать руководство пользователя страница 10

10

Santa Fe HC Installer’s & Owner’s Manual

Dehumidifier Limited Warranty

WARRANTOR:

 

Therma-Stor LLC 
PO Box 8680 
Madison, WI 53708 
Telephone: 1-800-533-7533

WHO IS COVERED:

 This warranty extends only  

to the original residential end-user of the Santa Fe HC 
Dehumidifier, and may not be assigned or transferred.

FIRST YEAR WARRANTY:

 Therma-Stor LLC warrants that, 

for one (1) year the Santa Fe HC dehumidifier will operate 
free from any defects in materials and workmanship, or 
Therma-Stor LLC will, at its option, repair or replace the 
defective part(s), free of any charge.

SECOND THROUGH FIFTH YEAR WARRANTY: 

Therma-Stor 

LLC further warrants that for a period of five (5) years, the 
condenser, evaporator, and compressor of the SANTA FE 
HC dehumidifier will operate free of any defects in material 
or workmanship, or Therma-Stor LLC, at its option, will 
repair or replace the defective part(s), provided that all 
labor and transportation charges for the part(s) shall be 
borne by the end-user. 

END-USER RESPONSIBILITIES: 

Warranty service must be 

performed by a Servicer authorized by Therma-Stor LLC. If 
the End-user is unable to locate or obtain warranty service 
from an  authorized Servicer, he should call Therma-Stor 
LLC at the above number and ask for the Therma-Stor LLC 
Service Department, which will then arrange for covered 
warranty service. Warranty service will be performed during 
normal working hours.

The End-user must present proof of purchase (lease) upon 
request, by use of the warranty card or other reasonable 
and reliable means. The end-user is responsible for normal 
care. This warranty only applies to residential applications, 
and does not cover any defect, malfunction, etc. resulting 

from misuse, abuse, lack of normal care, corrosion, 
freezing, tampering, modification, unauthorized or improper 
repair or installation, accident, acts of nature or any other 
cause beyond Therma-Stor LLCs reasonable control.

LIMITATIONS AND EXCLUSIONS:

 If any Santa Fe HC 

Dehumidifier part is repaired or replaced, the new part 
shall be warranted for only the remainder of the original 
warranty period applicable there to (but all warranty periods 
will be extended by the period of time, if any, that the 
Santa Fe HC Dehumidifier is out of service while awaiting 
covered warranty service).

UPON THE EXPIRATION OF THE WRITTEN WARRANTY 
APPLICABLE TO THE SANTA FE HC DEHUMIDIFIER OR 
ANY PART THEREOF, ALL OTHER WARRANTIES IMPLIED 
BY LAW, INCLUDING MERCHANTABILITY AND FITNESS 
FOR A PARTICULAR PURPOSE, SHALL ALSO EXPIRE. ALL 
WARRANTIES MADE BY THERMA-STOR LLC ARE SET 
FORTH HEREIN, AND NO CLAIM MAY BE MADE AGAINST 
THERMA-STOR LLC BASED ON ANY ORAL WARRANTY. IN 
NO EVENT SHALL THERMA-STOR LLC, IN CONNECTION 
WITH THE SALE, INSTALLATION, USE, REPAIR OR 
REPLACEMENT OF ANY SANTA FE HC DEHUMIDIFIER OR 
PART THEREOF BE LIABLE UNDER ANY LEGAL THEORY FOR 
ANY SPECIAL, INDIRECT OR CONSEQUENTIAL DAMAGES 
INCLUDING WITHOUT LIMITATION WATER DAMAGE (THE 
END-USER SHOULD TAKE PRECAUTIONS AGAINST SAME), 
LOST PROFITS, DELAY, OR LOSS OF USE OR DAMAGE TO 
ANY REAL OR PERSONAL PROPERTY.

Some states do not allow limitations on how long an 
implied warranty lasts, and some do not allow the 
exclusion or limitation of incidental or consequential 
damages, so one or both of these limitation may not apply 
to you.

LEGAL RIGHTS:

 This warranty gives you specific legal 

rights, and you may also have other rights which vary from 
state to state.

Содержание 4025081

Страница 1: ...1 08 For small usage P O Box 8680 Madison WI 53708 TOLL FREE 1 800 533 7533 www thermastor com sales thermastor com Free standing Moisture Control for Large Areas INSTALLER S OWNER S MANUAL HVAC INST...

Страница 2: ...80 F 60 RH Operating Temp 56 F min 100 F max Air Flow 323 CFM without external ducting 307 CFM 20 WG external static 285 CFM 40 WG external static Refrigerant Charge 1 lb 12 oz R22 Duct Connections Ro...

Страница 3: ...air flow path between the two rooms e g high door undercut louvered door or wall grill This eliminates the need to remote mount the humidity control WARNING Before installing the dehumidifier in the...

Страница 4: ...Route the drain hose through the trap as shown below in Figure 6 Position the trap on the hose approximately 12 away from the unit 4 Ducting 4 1 Optional Ducting Kit 10 collars may be attached to acc...

Страница 5: ...to the options and accessories table in this document 6 2 Blower Oiling The blower motor has been lubricated at the factory for many years of normal operation 7 Service WARNING Servicing the Santa Fe...

Страница 6: ...charge 3 Dirty air filter or air flow restricted 7 3 Defrost Thermostat The defrost thermostat is attached to the refrigerant suction tube between the accumulator and compressor It will automatically...

Страница 7: ...SANTA FE HC OWNER S AND INSTALLER S MANUAL 7 Santa Fe HC Installer s Owner s Manual 10 Wiring Diagram...

Страница 8: ...de panel of the dehumidifier by removing 9 hex screws Remove four screws on back of unit to expose electbox 4 Remove the 4 screws securing the wiring box to the inside of the blower end of the dehumid...

Страница 9: ...shown STEP 2 Pre drilled mounting holes are located near the bottom and on the same side of the unit as the drain hose STEP 5 Example of hose cut at a 45 angle The angle prevents the hose from sealin...

Страница 10: ...applies to residential applications and does not cover any defect malfunction etc resulting from misuse abuse lack of normal care corrosion freezing tampering modification unauthorized or improper re...

Страница 11: ...uced or transmitted in any form or by any means electronic or mechanical for any purpose without the express written permission of Therma Stor LLC 2008 Therma Stor LLC All rights reserved PO Box 8680...

Отзывы: