GENERAL TIPS ON PUMP INSTALLATION
Locate the pump as close to pool as practical and run suction line as direct as possible.
Secure pump to base with screws or bolts to reduce vibration and pipe stress.
Never overtighten pipe connections - use only pipe sealants formulated specifically
for plastics, i.e., Teflon tape, Permatex No. 2, etc.
Suction line should have continuous slope from lowest point in line.
Make sure suction joints are tight.
Suction pipe should be as large or larger than discharge pipe.
Damp, non-ventilated locations should be avoided.
Motors require free circulation of air to aid in cooling.
Ensure that the electrical supply available agrees with motor's voltage and is 50 Hz,
and that wire size is adequate for the KW rating and distance from power source.
Motor must always be properly earthed.
Electrical circuits must be supplied through a Residual Current Device- RCD (safety switch),
with a rated residual operating current of 30mA.
All electrical wiring must be performed by qualified electrical contractor and must conform to
electrical regulations and AS3000 wiring rules.
STARTING AND PRIMING INSTRUCTIONS
Fill strainer/housing with water to suction pipe level.
Never operate the pump without water. Water acts as a coolant and lubricant for the mechanical
shaft seal.
Open all suction and discharge lines and valves, as well as air bleed
(if available) on filter.
(The air that is to be displaced from the suction line must have some place to go).
CAUTION:
All suction and discharge valves must be open when starting the system.
Failure to do so could cause severe personal injury and/or property damage.
STARTING AND PRIMING INSTRUCTIONS
Turn on power and allow a reasonable time for priming. Five minutes is not unreasonable. (Priming
time depends on suction lift and horizontal length
of suction piping). If the pump will not start, or will not prime, see TROUBLE SHOOTING GUIDE on
back page.
NOTICE FOR SOLAR APPLICATIONS
A check valve must be fitted to the discharge of the pump when installed with solar system.