Please read these instructions thoroughly before use. Failure to follow instructions may 

result in equipment damage or failure, losses, injury or death.

 DANGER: 

To avoid possible electric shock:
•  If the power cord has been damaged, DO NOT operate, the AllClear™ G2 Filter unit should be replaced. 
•  Prior to installation, inspect the quartz sleeve and UVC bulb to ensure there was no damage during 

transportation. 

•  After installation, the AllClear™ G2 Filter should be examined to ensure there is no water on parts not 

intended to be wet. 

•  If the AllClear™ G2 Filter shows signs of any water leakage, immediately unplug it from the power source.
•  If the AllClear™ G2 Filter falls into the water, DO NOT reach for it. First unplug and then retrieve it.
•  Close supervision is necessary when the unit is used by or near children.

 WARNING: 

To reduce the risk of electric shock:
•  Connect only to a properly grounded receptacle, which is serviced by a Ground Fault Circuit 

Interrupter and never remove the ground pin from the plug. 

•  Provide a “drip loop” for the power cord. This is a loop in the cord below the level of the receptacle or 

plug that prevents water from traveling along the cord in the direction of the receptacle. 

•  ALWAYS unplug the AllClear™ G2 Filter from power source when it is not in use, and before installing, 

removing or servicing the AllClear™ G2 Filter components.

•  If an extension cord is necessary, a cord with a proper rating should be used. A cord may overheat if 

the cord is rated for less amperes or watts than the unit rating.

•  DO NOT immerse the AllClear™ G2 Filter or plug in water or attempt to use a wet plug. Minimum 

safety distance between unit and water is 6.5ft. 

•  The AllClear™ G2 Filter is NOT suitable for use in swimming pools, swimming ponds, or other 

situations where bodily contact is made with the water. Although the AllClear™ G2 Filter is designed 

for outdoor use, it should never be submerged in water.

Avoid contact with the UVC light. Light omitted can be harmful to the eyes and skin. 

 CAUTION: 

To reduce the risk of equipment damage or failure:
•  DO NOT place the AllClear™ G2 Filter in direct sunshine.
•  DO NOT place the AllClear™ G2 Filter near flammable or other dangerous materials or objects.
•  DO NOT use the AllClear™ G2 Filter for fluids other than water. 
•  ALWAYS unplug the unit if there is no water running through it to prevent over heating.
•  The AllClear™ G2 Filter is NOT submersible; do not place the AllClear™ G2 Filter where it might contact 

or fall into the water. Partial burial of the unit is recommended

•  DO NOT operate during freezing conditions. Disconnect, drain and store the AllClear™ G2 Filter in a 

protected location. 

•  DO NOT operate the AllClear™ G2 Filter with a pump larger than the maximum flow rate indicated 

by the filter specifications.  Operating with a pump larger than recommended can reduce the filters 

effectiveness and cause damage to the filter or UVC and will NOT be covered under warranty.

•  ALWAYS cap the backflush outlet when not in use to avoid unintended draining.

  

The Pond Guy® is not responsible for equipment damage or failure, losses, injury or death 

resulting from failure to follow safety precautions, misuse or abuse of equipment.

thepondguy.com  |  866-POND-HELP (766-3435)  

2

Содержание AllClear G2 2000

Страница 1: ...m 130051 AllClear G2 4500 Item 130052 TM ImportantInformation 2 PackageContents 3 TechnicalSpecs 3 HowitWorks 4 InstallingYourAllClear G2Filter 5 6 MaintainingYourAllClear G2Filter 7 11 Troubleshooting 12 ReplacementParts 14 15 WarrantyInformation 16 Table of Contents AllClear G2 2000 AllClear G2 3500 AllClear G2 4500 ...

Страница 2: ...tts than the unit rating DO NOT immerse the AllClear G2 Filter or plug in water or attempt to use a wet plug Minimum safety distance between unit and water is 6 5ft The AllClear G2 Filter is NOT suitable for use in swimming pools swimming ponds or other situations where bodily contact is made with the water Although the AllClear G2 Filter is designed for outdoor use it should never be submerged in...

Страница 3: ...NS AllClear G2 2000 120V 60 Hz 9Watts 2 000 GPH 2 000 1 1 Kink FreeTubing 16 15 D x 16 1 2 H AllClear G2 3500 2 650 GPH 3 500 15 D x 21 1 4 H AllClear G2 4500 3 600 GPH 4 500 15 D x 26 1 2 H AllClear G2 Series A AllClear G2 Filter B Fitting Kit C Backflush Cap may already be installed on backflush outlet A B C 15425 Chets Way Armada MI 48005 3 ...

Страница 4: ...efits Next water travels through layers of filter media arranged in alternating low and high density to provide mechanical and biological filtration The beneficial bacteria that grow in the media pads break down ammonia and nitrites that can diminish water quality and be harmful to aquatic life Finally the water exits the filter and proceeds back into your pond or waterfall thepondguy com 866 POND...

Страница 5: ...cation The AllClear G2 Filter is pressurized and may be installed in any location outside of the pond on a solid surface Avoid locations that are prone to water puddles or areas where the filter could fall into the pond It is recommended to partially bury the filter in the ground leaving only the filter top and clamps exposed Step 2 Mark Filter Location Set the filter in the selected location and ...

Страница 6: ...work with your plumbing to ensure maximum water flow Step 6 Connect the Plumbing Connect the plumbing coming from your pump into the inlet indicated on the filter and secure with a hose clamp Then connect plumbing that will return the water to your pond or waterfall into the outlet indicated on the filter and secure with a hose clamp Step 7 Plug in Pump and Filter Plug your pump into a GFCI protec...

Страница 7: ...lter slowly This compresses the filter media aiding in the discharge of debris Do this for 60 seconds or until the water exiting the backflush is clear MAINTAINING YOUR ALLCLEAR G2 FILTER Step 4 Once Water is Clear Unplug Pump Once the water is clear unplug the pump remove the discharge hose and cap the backflush outlet Step 5 Plug Pump In Restore power to both your pump and filter CLEANING THE FI...

Страница 8: ...ns of wear and tear WARNING Before performing any maintenance always unplug the AllClear G2 Filter from the power source Watch a video of the AllClear G2 Filter maintenance online www thepondguy com allclearg2 Tools Required 2 Phillips Screwdriver Replacement UV Bulb Soft damp cloth Descaler such as Pond Equipment Cleaner Replacement quartz sleeve if yours is damaged or cracked Replacement filter ...

Страница 9: ... Use a phillips screwdriver to remove the 4 screws securing the UV to the filter top REPLACING UV BULB AND CLEANING REPLACING THE QUARTZ SLEEVE Over time the effectiveness of the UV bulb will degrade We recommend replacing the UV bulb once a year even if the bulb operates to maintain maximum results The quartz sleeve should be cleaned yearly or when water clarity is reduced Note Condensation may f...

Страница 10: ...e oils from your hands can cause damage Step 6 Clean Quartz Sleeve Clean the quartz sleeve with a soft cloth or sponge The quartz sleeve should be cleaned yearly or when water clarity is reduced You may find the use of Pond Equipment Cleaner helpful for removing debris If the quartz sleeve if it is scratched damaged or cracked it must be replaced Step 5 Transfer Protective Cap Transfer the rubber ...

Страница 11: ...all the o ring quartz sleeve compression nut and screw to lock into place Step 8 Insert UV into Filter Insert the UV back into the filter top and secure with the 4 screws Note Screws must be tightened enough to engage the UV trigger you will hear a click when the UV is secure Step 9 Test UV Plug in the UV briefly to test it You will see a glow on the back of the UV indicating that it is operating ...

Страница 12: ...ndation for proper water flow on the Technical Specs chart Verify that filter media is not plugged with debris or needs cleaning Loss of water flow check the following Verify pump is not plugged with debris Verify filter media is not plugged with debris Verify filter is not leaking causing a loss of pressure Filter is leaking check the following Verify that the proper amount of water is flowing th...

Страница 13: ...NOTES 15425 Chets Way Armada MI 48005 13 ...

Страница 14: ...lClear G2 4500 A FilterTop Lid 130082 130082 130082 B UVTransformer 130095 130089 130096 C 9W UV Bulb 110306 110306 110306 D Quartz Sleeve 130074 130074 130074 I Operating Pieces 130090 130090 130090 J Gasket Kit 130087 130087 130087 K Screw Set 130091 130091 130091 L Fitting Kit 130088 130088 130088 M PVC Fitting Kit 130036 130036 130036 thepondguy com 866 POND HELP 766 3435 14 ...

Страница 15: ...ear G2 4500 E Cleaning Rods MeshTube 130092 130093 130094 F Filter Pad Set 130055 130056 130057 G Canister Clamp 130086 130086 130086 H Filter Canister Clamp w Filter Pads 130083 130084 130085 I Operating Pieces 130090 130090 130090 J Gasket Kit 130087 130087 130087 K Screw Set 130091 130091 130091 15425 Chets Way Armada MI 48005 15 ...

Страница 16: ...eipt The UVC bulb glass tube filter media and o rings are wearable items and are not covered by this warranty Abuse or misuse of this product or power cord alterations void all warranty Please call for a Return Authorization Number prior to returning product by calling our Customer Care Department at 866 766 3435 Failure to request an RMA number may result in delay or dismissal of your warranty cl...