background image

THELIN HEARTH PRODUCTS 

Gas Heater Repair Manual  

 

B-4 

CONVERSION KIT 

PARLOUR DIRECT VENT, GNOME  
DIRECT VENT, PARLOUR B VENT,  
AND ECHO 

Conversion from Natural Gas to Propane or  
Conversion from Propane to Natural Gas 

The  conversion  kit  contains:  Regulator,  Pilot  Orifice,  Main  Orifice, 
and Gas Type Labels. 

1. Shut off gas at the gas cock or shut off valve. 
2. Open door and remove the log set. 
3. To  change  orifices  on  the  Direct  Vent  stoves,  you  will  have  to 

remove the burner by removing two 1/4 x 20 hex bolts located on 
either side of the burner (see Figure 35 for Parlour and Figure 36 
for Gnome). 

4. With the burner removed you can access both orifices (see Figure 

35 and Figure 36). 

5. To change the pilot orifice and burner orifice, you will need both 

1/2” and 7/16” open end wrenches. 

IMPORTANT:

 Do not bend 

or move the gas tube when you unscrew the burner orifice. Make 
sure you re-seal orifice threads with 

yellow tape

 and 

do not allow 

tape to enter orifice opening

. The brass burner orifice is located 

on  the  right  side  of  stove  under  burner  on  Parlour  and  in  the 
middle  of  stove  on  Gnome.  You  will  need  both  wrenches  to 
remove the burner orifice. 

6. The pilot orifice is located on the left side and is in the middle of 

the  pilot  assembly.  To  remove  pilot  orifice,  use  the  1/2”  wrench 

and  unscrew  pilot  housing  and  lower  the  tube  down  to  remove 
orifice.  Place  the  new  pilot  orifice  over  the  end  of the  pilot  tube 
and  insert  into  the  base  of  the  pilot.  Screw  the  fitting  on  and 

tighten down snugly with the 1/2” open end wrench. (See 

Figure 

35 and Figure 36.) 

7. Remove  the  regulator  from  the  valve  (see  Figure  25).  The 

regulator is the knob that adjusts the flame from Hi to Lo, and it is attached to the valve with two screws 
as shown in Figure 25. The regulator and rubber gasket will come out together. Make sure you put the 
new gasket on the new regulator and screw the new regulator onto the valve (it will only go one way). 

8. Make sure you 

replace the labels

 on the back of the stove and on the valve. The labels are furnished with 

the conversion kit. 

Note:

 These instructions are for either the LP or natural gas valves and orifices. If you mix up the parts, you 

can identify the LP parts in the following way: the LP orifice has the smaller hole. The LP regulator is marked 
and has the numbers 11.0 and 2.7 stamped on it. The natural gas regulator is unmarked. 

WARNING 

This  conversion  kit  shall  be 
installed  by  a  qualified 
service agency in accordance 

with 

the 

manufacturer’s 

instructions  and  all  applicable 
codes and requirements of the 
authority  having  jurisdiction. 
If  the  information  in  these 
instructions  is  not  followed 
exactly,  a  fire,  explosion,  or 
production 

of 

carbon 

monoxide may result causing 
property  damage,  personal 
injury,  or  loss  of  life.  The 
qualified  service  agency  is 
responsible  for  the  proper 
installation  of  this  kit.  The 
installation  is  not  proper  and 
complete  until  the  operation 
of  the converted  appliance  is 
checked  as  specified  in  the 

manufacturer’s  instructions 

supplied with this kit.

SIT VALVE 

Содержание Echo Direct Vent

Страница 1: ...0 273 1976 Fax 530 273 3707 TH REF GEN 200 Rev A GAS HEATER SERVICE MANUAL Please familiarize yourself with entire manual before attempting a repair or adjustment of the heaters Parlour Direct Vent Gn...

Страница 2: ...as Valve Millivolt Check 7 VII Air Shutter Adjustment Correct Flame and Removal of Burner 7 VIII Restrictor Disks 8 IX Thermostat Hook Up 8 X Conversion Kits and Installation 8 XI Delayed Ignition Saf...

Страница 3: ...mination Locations OMNI 2004 33 Figure 23 Parlour B Vent Sit Valve Serial 543 OM 34 Figure 24 Parlour B Vent Robert Shaw Valve Serial 100 542 35 Figure 25 Parlour and Gnome Direct Vent SIT Valve 36 Fi...

Страница 4: ...TH PRODUCTS Gas Heater Service Manual 4 Figure 45 Parlour B Vent Wiring Diagram SIT Valve 58 Figure 46 Echo Venting Chart 59 Figure 47 Direct Vent Wiring Diagram 1995 2004 60 Figure 48 Direct Vent Dim...

Страница 5: ...ended venting systems for all Thelin Hearth Products gas heaters Venting properly is extremely important Ninety percent of problems with Direct Vent stoves relate to improper venting If you deviate fr...

Страница 6: ...re attempting to light the pilot Air pockets in the gas line will create problems when trying to light the pilot and burner 3 If you are not certain of the gas pressure for the stove always test the p...

Страница 7: ...T valve Figure 23 and Figure 25 Hook tube to these orifices after loosening internal screw and hook directly to manometer to check pressure Robert Shaw valves do not have these receptacles Pressure ca...

Страница 8: ...INSTALLATION All Thelin Hearth Products gas stoves can be converted from LP gas to natural gas or from natural gas to LP gas The kits consist of three parts plus a label indicating the change has bee...

Страница 9: ...y particular attention to the squirrel cage fan blades as these can accumulate dust and lint affecting the performance of the fan Clean as necessary 3 The wire harness and control knob connections sho...

Страница 10: ...35 per mile maximum one hundred miles round trip Qualification for Warranty Performance Return product or defective part with proof of purchase and narrative description of defect together with your...

Страница 11: ...WHETHER EXPRESS OR IMPLIED ARE HEREBY EXPRESSLY DISCLAIMED AND PURCHASER S RECOURSE IS EXPRESSLY LIMITED TO THE WARRANTIES SET FORTH WITHIN HOW TO USE THIS WARRANTY If you find this unit to be defect...

Страница 12: ...THELIN HEARTH PRODUCTS Gas Heater Service Manual 12 FIGURE 1 PARLOUR B VENT EXTERIOR VENT 1994 2001...

Страница 13: ...THELIN HEARTH PRODUCTS Gas Heater Service Manual 13 FIGURE 2 PARLOUR DIRECT VENT EXTERIOR VENT...

Страница 14: ...THELIN HEARTH PRODUCTS Gas Heater Service Manual 14 FIGURE 3 GNOME DIRECT VENT EXTERIOR VENT...

Страница 15: ...THELIN HEARTH PRODUCTS Gas Heater Service Manual 15 FIGURE 4 ECHO VENTING REQUIREMENTS...

Страница 16: ...THELIN HEARTH PRODUCTS Gas Heater Service Manual 16 FIGURE 5 ECHO VENTING REQUIREMENTS FIGURE 6 ECHO CO LINEAR FLEX SYSTEM...

Страница 17: ...THELIN HEARTH PRODUCTS Gas Heater Service Manual 17 FIGURE 7 PARLOUR DIRECT VENT PIPE CONFIGURATION...

Страница 18: ...THELIN HEARTH PRODUCTS Gas Heater Service Manual 18 FIGURE 8 GNOME DIRECT VENT PIPE CONFIGURATION...

Страница 19: ...Service Manual 19 FIGURE 9 ECHO PIPE CONFIGURATIONS E EC CH HO O HO OR RIIZ ZO ON NT TA AL L VE EN NT T WIIT TH H SN NO OR RK KL LE E E EC CH HO O HO OR RIIZ ZO ON NT TA AL L VE EN NT T E EC CH HO O...

Страница 20: ...VENT Roof Pitch H Min Ft Flat to 6 12 1 0 Over 6 12 to 7 12 1 25 Over 7 12 to 8 12 1 5 Over 8 12 to 9 12 2 0 Over 9 12 to 10 12 2 5 Over 10 12 to 11 12 3 25 Over 11 12 to 12 12 4 0 Over 12 12 to 14 12...

Страница 21: ...THELIN HEARTH PRODUCTS Gas Heater Service Manual 21 FIGURE 11 PARLOUR B VENT LABORATORY LISTING LABEL 1994 2001...

Страница 22: ...THELIN HEARTH PRODUCTS Gas Heater Service Manual 22 FIGURE 12 PARLOUR DIRECT VENT LABORATORY LISTING LABEL 1995 2004...

Страница 23: ...THELIN HEARTH PRODUCTS Gas Heater Service Manual 23 FIGURE 13 PARLOUR DIRECT VENT LABORATORY LISTING LABEL OMNI 2004...

Страница 24: ...THELIN HEARTH PRODUCTS Gas Heater Service Manual 24 FIGURE 14 GNOME DIRECT VENT LABORATORY LISTING LABEL 1995 2004...

Страница 25: ...THELIN HEARTH PRODUCTS Gas Heater Service Manual 25 FIGURE 15 GNOME DIRECT VENT LABORATORY LISTING LABEL OMNI 2004...

Страница 26: ...THELIN HEARTH PRODUCTS Gas Heater Service Manual 26 FIGURE 16 ECHO LABORATORY LISTING LABEL TO 3 6 2007...

Страница 27: ...THELIN HEARTH PRODUCTS Gas Heater Service Manual 27 FIGURE 17 ECHO LABORATORY LISTING LABEL 3 7 2007 TO PRESENT...

Страница 28: ...THELIN HEARTH PRODUCTS Gas Heater Service Manual 28 FIGURE 18 PARLOUR DIRECT VENT VERTICAL PIPE INSTALLATION AIR INTAKE RESTRICTOR DISKS...

Страница 29: ...THELIN HEARTH PRODUCTS Gas Heater Service Manual 29 FIGURE 19 PARLOUR DIRECT VENT STOVE WITH BURNER...

Страница 30: ...Install rear log 2 against brick panel and center right to left 3 Place small log 3 with the notch on the bottom setting of the ledge indicated in the illustration 4 Rest the Y log 4 on top of the sma...

Страница 31: ...e Manual 31 FIGURE 20 PYROTECH LOG PLACEMENT CONTINUED 5 Place the front log 5 against the Y log in the notch shown in the illustration with the bottom end up against the lip of the door opening Note...

Страница 32: ...t form the centerline of the termination 18 minimum 46 cm D Clearance to an unventilated soffit 12 minimum 30 cm E Clearance to an outside corner 9 23 cm F Clearance to an inside corner 9 23 cm G Do n...

Страница 33: ...THELIN HEARTH PRODUCTS Gas Heater Service Manual 33 FIGURE 22 VENT TERMINATION LOCATIONS OMNI 2004...

Страница 34: ...THELIN HEARTH PRODUCTS Gas Heater Service Manual 34 FIGURE 23 PARLOUR B VENT SIT VALVE SERIAL 543 OM Pressure Test Taps...

Страница 35: ...THELIN HEARTH PRODUCTS Gas Heater Service Manual 35 FIGURE 24 PARLOUR B VENT ROBERT SHAW VALVE SERIAL 100 542...

Страница 36: ...THELIN HEARTH PRODUCTS Gas Heater Service Manual 36 FIGURE 25 PARLOUR AND GNOME DIRECT VENT SIT VALVE...

Страница 37: ...THELIN HEARTH PRODUCTS Gas Heater Service Manual 37 FIGURE 26 PARLOUR AND GNOME DIRECT VENT ROBERT SHAW VALVE...

Страница 38: ...THELIN HEARTH PRODUCTS Gas Heater Service Manual 38 FIGURE 27 DIAGRAM OF ECHO CONTROL COMPONENTS SIT VALVE...

Страница 39: ...Service Manual 39 FIGURE 28 DIAGRAM OF ECHO CONTROL COMPONENTS AIR RESTRICTOR 1 15 Open 2 25 Open 3 85 Open Position 1 Use Only When 2 or More Elbows in Pipe Run Position 2 1 12 Ft Position 3 12 Ft A...

Страница 40: ...llows Natural Gas 36 up to 4 500 elevation LP Gas 52 up to 4 500 elevation Recommendation If installing at higher altitudes Thelin Hearth Products recommends at the discretion of the installer Natural...

Страница 41: ...THELIN HEARTH PRODUCTS Gas Heater Service Manual 41 FIGURE 30 PARLOUR B VENT LOG PLACEMENT AND AIR SHUTTER ADJUST...

Страница 42: ...THELIN HEARTH PRODUCTS Gas Heater Service Manual 42 FIGURE 31 PARLOUR DIRECT VENT LOG PLACEMENT AND AIR SHUTTER ADJUST...

Страница 43: ...THELIN HEARTH PRODUCTS Gas Heater Service Manual 43 FIGURE 32 GNOME DIRECT VENT LOG PLACEMENT AND AIR SHUTTER ADJUST...

Страница 44: ...ocedure for installing the Echo log set 1 Remove top lid and top from stove Unhook glass door latch at bottom of stove and lift out glass door 2 Install Log 1 as per picture below 3 Install Log 2 as p...

Страница 45: ...HO STOVE WITH LOG PLACEMENT CONTINUED 7 Install Ember Basket as per picture below 8 Install Embers as per picture below Make sure all logs are secure and not impinging on the burner tubes Re install g...

Страница 46: ...procedure for installing the Echo log set 1 Remove top lid and top from stove Unhook glass door latch at bottom of stove and lift out glass door 2 Install Log 1 as per picture below 3 Install Log 2 a...

Страница 47: ...TS Gas Heater Service Manual 47 FIGURE 34 ECHO STOVE WITH LOG EMBER TRAY PLACEMENT CONT D 7 Make sure all logs are secure and not impinging on the burner Re install glass door top and lid You are read...

Страница 48: ...as follows Natural Gas 36 up to 4 500 elevation LP Gas 52 up to 4 500 elevation Recommendation If installing at higher altitudes Thelin Hearth Products recommends at the discretion of the installer Na...

Страница 49: ...THELIN HEARTH PRODUCTS Gas Heater Service Manual 49 FIGURE 36 PARLOUR AND GNOME STOVE WITH BURNER REMOVED...

Страница 50: ...THELIN HEARTH PRODUCTS Gas Heater Service Manual 50 FIGURE 37 LOCATION OF ECHO PILOT BURNERS AND AIR SHUTTER...

Страница 51: ...PRODUCTS Gas Heater Service Manual 51 FIGURE 38 DIRECTIONS FOR ENABLING ECHO DOOR OPENING AND SECURING DOOR 1 Remove stove top to access glass door Figure 39 2 Unhook latch at bottom of door 3 Lift do...

Страница 52: ...THELIN HEARTH PRODUCTS Gas Heater Service Manual 52 FIGURE 39 DELAYED ECHO IGNITION SAFETY SHUT DOWN...

Страница 53: ...RESTRICTOR DISKS IN PARLOUR AND GNOME 1995 2004 1 Burner must be removed to access restrictor disks 2 Loosen 7 16 nut and adjust disk to cover air intake tube opening 3 The higher the vertical pipe ru...

Страница 54: ...THELIN HEARTH PRODUCTS Gas Heater Service Manual 54 FIGURE 41 LOCATION OF RESTRICTOR DISKS IN PARLOUR AND GNOME 2004...

Страница 55: ...FAN REMOVAL 1 Remove outer jacket label wires before removing 2 Disconnect wires to fan motor 3 Remove two screws at base of a mounting bracket 4 Install new fan on mounting bracket and re mount brac...

Страница 56: ...AFETY SHUT DOWN 2004 This unit is equipped with a safety shut down system that will disable the stove in the event pressure builds up and the stove ignites with delayed combustion If this happens you...

Страница 57: ...THELIN HEARTH PRODUCTS Gas Heater Service Manual 57 FIGURE 44 PARLOUR B VENT WIRING DIAGRAM ROBERT SHAW VALVE...

Страница 58: ...THELIN HEARTH PRODUCTS Gas Heater Service Manual 58 FIGURE 45 PARLOUR B VENT WIRING DIAGRAM SIT VALVE...

Страница 59: ...THELIN HEARTH PRODUCTS Gas Heater Service Manual 59 FIGURE 46 ECHO VENTING CHART...

Страница 60: ...THELIN HEARTH PRODUCTS Gas Heater Service Manual 60 FIGURE 47 DIRECT VENT WIRING DIAGRAM 1995 2004...

Страница 61: ...THELIN HEARTH PRODUCTS Gas Heater Service Manual 61 FIGURE 48 DIRECT VENT DIMENSIONS...

Страница 62: ...THELIN HEARTH PRODUCTS Gas Heater Repair Manual A 1 APPENDIX A SIT VALVE TROUBLESHOOTING GUIDE...

Страница 63: ...THELIN HEARTH PRODUCTS Gas Heater Repair Manual B 1 APPENDIX B CONVERSION KIT INSTRUCTIONS...

Страница 64: ...this conversion 7 Place the new pilot orifice over the end of the pilot tube and insert into the base of the pilot Thread the fitting on and tighten down snugly with a 1 2 open ended wrench 8 Remove t...

Страница 65: ...insert into the base of the pilot Screw the fitting on and tighten down snugly with the 1 2 open end wrench See Figure 35 and Figure 36 7 Remove the regulator from the valve see Figure 26 The regulat...

Страница 66: ...and insert into the base of the pilot Screw the fitting on and tighten down snugly with the 1 2 open end wrench See Figure 35 and Figure 36 7 Remove the regulator from the valve see Figure 25 The regu...

Отзывы: