360° Flush Mount Wall  

PIR Light Controller

Model: PDFM1500

Содержание Timeguard PDFM1500

Страница 1: ...I n s t a l l a t i o n O p e r a t i n g I n s t r u c t i o n s 360 Flush Mount Wall PIR Light Controller Model PDFM1500 ...

Страница 2: ...al Specifications 230V AC 50 Hz This PIR is of Class ll Construction and must not be earthed Motion Detection Range Up to 10 metres diameter 4 5m Radius at a 3m mounting height Presence Detection Range Up to 3 metres diameter 1 5m Radius at a 3m mounting height Detection Angle 360 Maximum Switching Load 1500W Halogen Fluorescent Lighting 420W LED Lighting 420W Discharge Lighting SON HQI 250W Fan L...

Страница 3: ...on range and direction The sensor is more sensitive to movement ACROSS its field of vision than to movement directly TOWARDS See diagram B Therefore position the unit so that the sensor looks ACROSS the likely approach path Reflective surfaces i e pools of water or white painted walls may cause false activation under extreme conditions Diagram A Diagram B Side View Top View 3m 360 More sensitive L...

Страница 4: ...conductors are sleeved See section 6 Connection Diagram When wiring is complete fit the cable clamp wiring cover to the sensor unit with the 2 screws provided See diagram E The adjustment knobs located beneath the sensor head see diagram C are factory set to Walk Test Mode Double check they are set as follows TIME Fully anti clockwise Test mode DUSK Fully clockwise Note Make sure the Lux and Time ...

Страница 5: ...rea L1 N Switched Load OUT 230V AC 50Hz Mains Supply IN L N Locating springs pulled back w n a 0Hz ply Sensor Cable clamp Wiring cover Locating springs fitted position Min 12mm Max 20mm re nsitive Time On Lux Time On settin g Lux Dusk Daw n settin g Levering area L1 N Switched Load OUT 230V AC 50Hz Mains Supply IN L N Locating springs pulled back Time On Lux Time On settin g Lux Dusk Daw n settin ...

Страница 6: ...s fitted position Min 12mm Max 20mm 5 6 Connection Diagram Connect cables to the terminal block as follows 230V AC 50Hz Mains Supply Live Brown or Red to L Neutral Blue or Black to N Load Switch Live Brown or Red to L1 Neutral Blue or Black to N N N 230V AC 50Hz MAINS SUPPLY LOAD L N ISOLATION SWITCH L1 L ...

Страница 7: ...onds each time This allows testing to be carried out to establish whether the sensor is covering the required area Walk across the location the sensor is fitted to establish the detection area The sensor will detect you approximately up to 9 metres forward at mounting height of 1m As you cross a detection zone the lamp will illuminate Now stand still until the lamp extinguishes this should take ap...

Страница 8: ...eved by the procedure below 1 Set the DUSK control knob fully anti clockwise 2 When the ambient light level reaches the level of darkness at which you wish the lamp to become operative i e at dusk SLOWLY rotate the control in a clockwise direction until a point is reached where the lamp illuminates 3 Leave the control set at this point At this position the unit should become operative at approxima...

Страница 9: ...n off at the isolation switch Turn back ON again after 30 seconds Leave for approximately 15 minutes If light activates check area for false activation from heat wind or reflective source Check that the power is switched ON at the power supply or isolation switch Turn OFF the power to the unit and check the wiring connections See section 6 Wiring Diagram Check the lamp If the lamp has failed repla...

Страница 10: ...t in the area may be too bright to allow operation at the current DUSK setting During the hours of darkness adjust the DUSK control slowly clockwise until the lamp illuminates See section 7 Setting Up Adjust the DUSK Control setting anti clockwise to lower the level of ambient light required for activation ...

Страница 11: ...h proof of purchase and it will be replaced free of charge For years 2 and 3 or any difficulty in the first year telephone the helpline on 020 8450 0515 Note A proof of purchase is required in all cases For all eligible replacements where agreed by Timeguard the customer is responsible for all shipping postage charges outside of the UK All shipping costs are to be paid in advance before a replacem...

Страница 12: ... csc timeguard com For a product brochure please contact If you experience problems do not immediately return the unit to the store Telephone the Timeguard Customer Helpline Qualified Customer Support Co ordinators will be on line to assist in resolving your query HELPLINE 020 8450 0515 or email helpline timeguard com www timeguard com ...