background image

 

Connecting TC 649 E to the network

 

 

TC 649 E Manual 

 

12 

 

 

 

The TC 649 E login screen appears. 

      
 
 
 
 
 
 
 
 
 
 
 

 

Enter 

admin

 as the user name. 

 

Enter the default password (

admin

) or your own password as applicable.  

 

Click on 

Log in

 or press the Enter key. 

 

Set the IP address to the static address you require via Settings 

 Network 

settings – for more information, see 

Network settings 5.2.1.1. DHCP 

 

static 

 

If you still cannot access the TC 649 E device, check the proxy settings and 
contact the system administrator if necessary. 

 
Once you have changed the TC 649 E's IP address to a static address: 

 

Move the network cable from the Service interface to the Ethernet interface. 

 

Change your computer's network adapter to the required address. 

 

To do this, see the steps mentioned above. 
 

 

Restart the device by disconnecting it briefly from the power supply. 

 

 

 

Содержание TC 649 E

Страница 1: ...2019 10 11_310547 01 Manual for TC 649 E Version 1 ...

Страница 2: ...Connecting TC 649 E to the router 8 3 2 Connecting TC 649 E using a point to point connection 9 4 Navigation 13 5 Controls and menu 14 5 1 Start 14 5 2 Settings 15 5 3 Control 19 5 4 Info 22 5 5 Log out 22 5 6 Password forgotten 22 5 7 Switching language 23 6 Appendix 24 6 1 Default settings 24 6 2 Troubleshooting 24 6 3 Specifications 25 6 4 Glossary 25 6 5 Use of open source software 26 7 Contac...

Страница 3: ... is installed in the network via an integrated web server The control box is integrated into the company s own network via VPN this means that you can operate your control boxes in a secure environment You can use simple functions with the control box such as astronomically controlled lighting time controlled access points and temperature reduction for heating units during the day and at night Cen...

Страница 4: ...rol box can be called up on a desktop PC or a mobile end device such as a tablet or smartphone The following browsers operating systems are supported Browsers o Google Chrome from version 69 onwards Operating systems o Microsoft Windows o Apple iOS from version 10 onwards o Google Android from version 7 onwards ...

Страница 5: ...hout any external software Administration via web interface The TC 649 E can be easily configured via the web Update firmware Firmware can be easily updated via the web interface 1 4 Housing 1 4 1 Top Name Status Meaning Web server Off The web server for the web interface is switched off On The web server for the web interface is switched on Flashing The web server for the web interface is startin...

Страница 6: ...server Relay Off All relays are switched off On One or more relays are switched on PWR TLS Off The TC 649 E is switched off Flashing The TC 649 E is switched on 1 4 2 Front The socket for the power supply both network interfaces service Ethernet and the socket for relays C1 and C3 are located on the front of the device 1 4 3 Back The socket for relays C2 and C4 is located on the back of the device...

Страница 7: ...Start up TC 649 E Manual 7 2 Start up Please refer to the enclosed installation and operating instructions for information on how to connect the device and carry out initial operation ...

Страница 8: ...k cable RJ45 connector into the right hand Ethernet socket on the TC 649 E Open the web browser Google Chrome and load the page http serial number for the TC 649 E Example http DTHE0200001111 or http 192 168 138 3 http DTHE0200001111 or http 192 168 137 3 If you cannot reach the device via the hostname it is probably because your router is unable to resolve the hostname You can use the user interf...

Страница 9: ...ur PC directly to the TC 649 E control box P2P using a point to point connection Your PC must have a static IP address As the default configuration for the TC 649 E control box is for it to be connected to a router the device must be reconfigured first Change the PC network interface from DHCP to static Open the network connection Press the Windows key R Enter ncpa cpl Double click on the network ...

Страница 10: ...Connecting TC 649 E to the network TC 649 E Manual 10 Click on Properties Double click on Internet Protocol Version 4 TCP IPv4 ...

Страница 11: ...owing IP address Enter the required information see screenshot Close all windows by pressing OK Plug the network cable RJ45 connector into the computer Plug the other end of the network cable RJ45 connector into the left hand Service socket on the TC 649 E Open the web browser and load the following page Example http 192 168 138 3 ...

Страница 12: ...ngs for more information see Network settings 5 2 1 1 DHCP static If you still cannot access the TC 649 E device check the proxy settings and contact the system administrator if necessary Once you have changed the TC 649 E s IP address to a static address Move the network cable from the Service interface to the Ethernet interface Change your computer s network adapter to the required address To do...

Страница 13: ... main way to navigate around the user interface is via the menu bar at the top of the screen You can access all the TC 649 E settings via this navigation bar Menu items marked with a contain sub menu items which can be called up with a single click ...

Страница 14: ...nu item If the main menu item contains sub menu items a drop down menu will open You can then click on the sub menu item you want 5 1 Start Detailed device information is displayed on the start page This information cannot be changed here To change the settings use the corresponding menu items under Settings or Control ...

Страница 15: ...erface Ethernet 5 2 1 1 DHCP static To change the network interface from DHCP to static Untick the Use DHCP field Enter a valid IPv4 address the corresponding subnet mask and a standard gateway if applicable Click on Save to confirm changes To configure and use the NTP server proceed as follows Tick the box next to Use NTP server Enter the relevant NTP server address Click on Save to confirm chang...

Страница 16: ...ilable after settings have been saved Changes to the network settings may result in loss of contact with the control box 5 2 2 Setting time date country You can use the following menu to set the time and date and to store a location for the astro functionality Changing the time The date and time can only be changed if the NTP server is deactivated Click the following field A pop up window appears ...

Страница 17: ...Save 5 2 3 Updating firmware You can run a device update in this menu You can run the device update either online Internet connection required or offline not on mobile devices A firmware update can only be carried out via the desktop application Online update Click on the Check for updates button A message appears if an update is available Then click on Start firmware update Press Yes to confirm a...

Страница 18: ...rreparable damage to the device Offline update Drag and drop the firmware package provided by Theben AG into the dashed field Then click on Start firmware update Press Yes to confirm and carry out the update The update is downloaded and installed automatically Once the update has completed successfully you will be redirected automatically to the login page The update will take 3 to 5 minutes The w...

Страница 19: ...matically logged out and redirected to the login page Log in using your new password 5 3 Control 5 3 1 Direct connection Direct connection is only possible with an active switching profile Each channel can be switched individually Status Function PERM OFF The channel is switched off and cannot be changed via the programmed switching times PERM ON The channel is switched on and cannot be changed vi...

Страница 20: ...mode in the drop down menu PERM OFF PERM ON AUTO The channel switches to the desired status The current relay status is displayed 5 3 2 ot2 download You can transfer the ot2 file from the OBELISK software to the control box here You can only download the ot2 file via the desktop browser ...

Страница 21: ...n order to transfer the ot2 file to the TC 649 E The ot2 file download can take a while The time required for the download depends on the number of switching times 5 3 3 Astro offset The offset for astro switching times can only be set for channels which use the astro functionality The astro functionality for the individual channels must be stored in the OBELISK software The astro offset can be ch...

Страница 22: ...r interface click on the Log out button in the top right hand corner of the screen You will then be redirected to the login page 5 6 Password forgotten If you have forgotten your password click on Forgotten password on the login page This will redirect you to the page where you can reset your password To reset your password proceed as follows Enter your device s serial number in the serial number ...

Страница 23: ...n and the password admin 5 7 Switching language You have the option of setting a different interface language on the TC 649 E To do this click on the language in the middle of the screen at the bottom and select your chosen language The interface language changes to the desired language ...

Страница 24: ...ected to the supply voltage Check the network connection between the TC 649 E and the PC or router Check the network configuration of your TC 649 E and or your PC or router 6 2 2 How can I tell if my TC 649 E is working properly Your TC 649 E is ready for operation if the PWR TLS LED is flashing and the LED for the web server is lit up permanently 6 2 3 What can I do if I forget my password Reset ...

Страница 25: ... operation 25 C to 55 C Threshold for storage and transport 25 C to 70 C Air humidity 95 non condensing Protection class II subject to designated installation Protection rating IP 30 6 4 Glossary DNS Domain Name System A service which converts the domain name into IP addresses Domain name The descriptive name for an Internet or network address Gateway Component which establishes a connection betwe...

Страница 26: ...ix TC 649 E Manual 26 6 5 Use of open source software This product uses open source software OSS A list of the OSS components used and their licence type and version can be found at https www theben de tc 649 ...

Страница 27: ... 649 E Manual 27 7 Contact Theben AG Hohenbergstr 32 72401 Haigerloch GERMANY Phone 49 7474 692 0 Fax 49 7474 692 150 Hotline Phone 49 7474 692 369 hotline theben de Addresses telephone numbers etc www theben de ...

Отзывы: