3
The main functions
Program
Set departure time
Enter/change the name of
the device/parking space
Send settings to timer
Program
– Preheating time 2 h or 4 h
– Activate car charging time
(for all hybrid and
e-vehicles)
Display of energy consumption
Display energy consumption (± 10 %)
Data for 1 day, 7 days, 28 days
(indicated in kWh and price/kWh)
retrieve current data
Setting and FAQ
FAQ
Operating instructions on the
Internet
Favourite ▻ only appears if
Locked user
is activated
Setting
–
Locked user
(for private
use)
– Factory setting
Send factory setting
L
Time and all energy consump-
tions are deleted
Normal mode and „Locked user mode“
In normal mode, the device identifiers are not stored and
the ownership rights can be taken over by third parties, for
example if one user has left the parking space and a second
wants to use it.
Remote connections in normal mode are maintained until one
of the following conditions occurs:
•
Mode 2 h elapsed +2 h
•
Mode 4 h elapsed +2 h
•
Mode "Charge car" > 1 h of heating time
•
if the manual connection is made by a person using a
scan or the button combination.
•
if the +/– buttons and the Mode button are used to
change the reservation manually.
▻ For further operation, the timer must be
reconnected
.
In
"Locked user mode"
, i.e.
Locked user
must be activated in
menu ▻ Settings,
the device identifiers will be saved. The devices can be ope
-
rated via the favourites on the start page without new pairing
(favourite = yellow star).
8. Technical data
Operating voltage:
230 V AC
Frequency:
50 Hz
Standby:
0.4 W
Switching capacity:
16 A (at 230 V AC, cos
ϕ
= 1), 3680 W
Switching capacity:
2 A (at 230 V AC, cos
ϕ
= 0.6)
Protection rating:
IP 20 in accordance with EN 60529
Protection class:
I in accordance with EN 60730-1
subject to designated installation
Operating temperature:
–40 °C … +50 °C
Type of contact:
NO contact
Switching accuracy:
to the second
Power reserve:
4 h
Time accuracy:
synchronised with mains
Mode of operation:
Type 1 BSTU
Rated impulse voltage:
4 kV
Pollution degree:
2
Software:
Class A
Range:
15 m on open air test site
Transmission frequency:
2400 MHz
Transmission power:
2.5 mW; class 2
Theben AG herewith declares that this type of radio installation
complies with Directive 2014/53/EU. The complete text of the
EU Declaration of Conformity is available at the following Internet
address:
www.theben.de/red-konformitaet
Cleaning and service
Only use a dry, soft cloth to clean the device surface.
Do not use any cleaning agents or solvents.
Disposal
Dispose of device in environmentally sound manner
(electronic waste)
9. Contact
Theben Oy
Liikkalankuja 6
00950 Helsinki
FINLAND
Phone: +358 9 4242 7877
E-mail: [email protected]