background image

3

The main functions

Program

Set departure time

Enter/change the name of 

the device/parking space 

Send settings to timer

Program

– Preheating time 2 h or 4 h

– Activate car charging time  

    (for all hybrid and  

    e-vehicles)

Display of energy consumption

Display energy consumption (± 10 %)

Data for 1 day, 7 days, 28 days 

 

(indicated in kWh and price/kWh)

retrieve current data

Setting and FAQ

FAQ

Operating instructions on the 

Internet

Favourite ▻ only appears if 

Locked user

 is activated

Setting

– 

Locked user

 (for private  

    use)

– Factory setting

Send factory setting

 

L

Time and all energy consump-

tions are deleted

Normal mode and „Locked user mode“

In normal mode, the device identifiers are not stored and 

the ownership rights can be taken over by third parties, for 

example if one user has left the parking space and a second 

wants to use it.

Remote connections in normal mode are maintained until one 

of the following conditions occurs:

 

Mode 2 h elapsed  +2 h

 

Mode 4 h elapsed  +2 h

 

Mode "Charge car"  > 1 h of heating time

 

if the manual connection is made by a person using a 
scan or the button combination.

 

if the +/– buttons and the Mode button are used to 
change the reservation manually.

 

▻ For further operation, the timer must be 

reconnected

.

In 

"Locked user mode"

, i.e. 

Locked user

 must be activated in 

menu ▻ Settings, 

the device identifiers will be saved. The devices can be ope

-

rated via the favourites on the start page without new pairing 

(favourite = yellow star).

8.  Technical data

Operating voltage: 

230 V AC

Frequency:

50 Hz

Standby: 

0.4 W

 

Switching capacity:

16 A (at 230 V AC, cos 

ϕ

 = 1), 3680 W

Switching capacity:

2 A (at 230 V AC, cos 

ϕ

 = 0.6)

Protection rating: 

IP 20 in accordance with EN 60529

Protection class: 

I in accordance with EN 60730-1 

subject to designated installation

Operating temperature: 

–40 °C … +50 °C 

Type of contact:

NO contact

Switching accuracy:

to the second

Power reserve:

4 h

Time accuracy:

synchronised with mains

Mode of operation:

Type 1 BSTU

Rated impulse voltage: 

4 kV

Pollution degree: 

2

Software:

Class A

Range:

15 m on open air test site

Transmission frequency:

2400 MHz

Transmission power:

2.5 mW; class 2

Theben AG herewith declares that this type of radio installation 

complies with Directive 2014/53/EU. The complete text of the 

EU Declaration of Conformity is available at the following Internet 

address:  

www.theben.de/red-konformitaet

Cleaning and service

 

†

Only use a dry, soft cloth to clean the device surface.

 

†

Do not use any cleaning agents or solvents.

Disposal

 

†

Dispose of device in environmentally sound manner  

(electronic waste)

9.  Contact

Theben Oy

Liikkalankuja 6

00950 Helsinki

FINLAND

Phone: +358 9 4242 7877

E-mail: [email protected]