background image

6

Resetting the clock thermostat

¾

†

Press the 4 buttons simultaneously

 

You can choose between KEEP PROGRAM and DELETE 
PROGRAM

6.  Technical data

Operating voltage: 

230V AC, +10 % / -15 %

Frequency: 

50–60 Hz

Power consumption: 

1,4 W

Standby output: 

1,36 W

Switch output: 

switching of any phase is  

permitted

Voltage at sensor input:

Safety Extra-Low Voltage (SELV) 

approx. 3.5 V

Contact: 

Changeover contact

Contact gap: 

<3 mm (μ)

Max switching capacity: 

10 A/ 250 V~, cos 

ϕ

 = 1; 

2 A/ 250 V~, cos 

ϕ

 = 0,6

switching capacity: 

10 mA/230 V AC 

100 mA/12 V AC/DC

Sensor type: 

NTC,

sensor length:

max. 50 m

Mode of operation: 

type 1 B in accordance with 

60730-1

Operating temperature: 

0 °C ... +50 °C

Protection class: 

II in accordance with EN 

60730-1 subject to correct 

installation

Protection rating: 

IP 20 in accordance with  

EN 60529

Time accuracy (typical):

 ≤ ± 0.25 s/day (25 °C)

Power reserve: 

10 years at +20 °C

Pollution degree: 

2

Rated impulse withstand voltage: 

4 kV

7.  Contact

Theben AG

Hohenbergstr. 32

72401 Haigerloch

GERMANY

Tel. +49 7474 692-0

Fax +49 7474 692-150

Hotline

Tel. +49 7474 692-369

[email protected]