Resetting the clock thermostat
¾
Press the 4 buttons simultaneously
▻
You can choose between KEEP PROGRAM and DELETE
PROGRAM
6. Technical data
Operating voltage:
230V AC, +10 % / -15 %
Frequency:
50–60 Hz
Power consumption:
1,4 W
Standby output:
1,36 W
Switch output:
switching of any phase is
permitted
Voltage at sensor input:
Safety Extra-Low Voltage (SELV)
approx. 3.5 V
Contact:
Changeover contact
Contact gap:
<3 mm (μ)
Max switching capacity:
10 A/ 250 V~, cos
ϕ
= 1;
2 A/ 250 V~, cos
ϕ
= 0,6
switching capacity:
10 mA/230 V AC
100 mA/12 V AC/DC
Sensor type:
NTC,
sensor length:
max. 50 m
Mode of operation:
type 1 B in accordance with
60730-1
Operating temperature:
0 °C ... +50 °C
Protection class:
II in accordance with EN
60730-1 subject to correct
installation
Protection rating:
IP 20 in accordance with
EN 60529
Time accuracy (typical):
≤ ± 0.25 s/day (25 °C)
Power reserve:
10 years at +20 °C
Pollution degree:
2
Rated impulse withstand voltage:
4 kV