![The Splash Lab TSL.C.050 Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/the-splash-lab/tsl-c-050/tsl-c-050_installation-and-maintenance_1100794016.webp)
troubleshooting
Corrective Actions for Initial Installation Failures
Water does not flow / Cannot hear valve open
+
There is no power to valve or sensor
+
Check that cables are connected
+
Check that transformer is operating and supplying 6 volts
+
Sensor range is incorrect
+
Adjust sensor setting (see pages 11 and 12)
Water does not flow / Valve can be heard to open
+
Water supply is blocked to valve
+
Check and clean filter on solenoid valve
+
Check water supply for any blockages or restrictions
+
Water pressure is too low
+
Check pressure of water supply
Water does not flow / Sensor light is flashing all the time
+
Supply voltage has dropped below 5.4V
+
Check power supply and if necessary replace transformer
We are always looking to improve. If these steps
did not solve your problem please contact us
and we will endeavor to help.
Tel: 310 410 5008
Email: [email protected]