troubleshooting

  Problem

  Water not flowing

  Cause

  Range is too short

  Solution

  Increase detection range

  Range is too long

  Decrease detection range

  Sensor is dirty or obstructed

  Clean sensor and remove obstruction

  Tap is in security time-out mode

  Replace batteries or restore power supply

  Solenoid valve is incorrectly connected  
  (polarity reversed)

  Reconnect solenoid valve with correct  
  polarity

  Sensor is detecting reflections from basin  
  or another object

  Reduce detection range or remove object  
  causing reflection

  Water flow does not stop when user’s hands  
  are within range

  Debris or scale in solenoid valve

  Remove solenoid and clean or replace valve

  Cables between PSU and solenoid are  
  disconnected

  Reconnect cables

  Solenoid valve is incorrectly connected  
  (polarity reversed)

  Reconnect solenoid valve with correct  
  polarity

  Water supply pressure is too high

  Reduce water pressure

  Slow response time when opening or closing  
  solenoid valve

  Cable connections loose.

  Check all connections are properly fitted  
  together

  Debris or scale in solenoid valve

  Remove solenoid and clean and  
  replace valve

  Sensor is detecting reflections from basin  
  or other object

  Reduce detection range or remove object  
  causing reflection

  Water flow reduced

  Aerator is blocked with scale or debris

  Remove aerator and clean or replace

  Debris or scale in solenoid valve.

  Remove solenoid and clean and  
  replace valve

Содержание TSL.960 Series

Страница 1: ...TSL 960 deck mounted sensor tap installation maintenance...

Страница 2: ...Box Contents 5 Diagram 6 Technical Data 8 Before You Install 9 Dimensions 10 How To Install 14 Commissioning Operation 15 Troubleshooting 16 Cleaning 17 Maintenance 18 Warranty 19 Contact Details con...

Страница 3: ...ns WARNING Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer see back page for more details Ensure plumbing is installed correctly before act...

Страница 4: ...le 3 Solenoid valve assembly 4 Power supply 5 Hex wrench 6 Battery 7 Battery holder 8 Flow regulator 9 Filter 10 Aerator 11 Fixing nut 12 Sealing washer 13 Anti rotation plate 14 Aerator key 4 TSL 960...

Страница 5: ...diagram 5 TSL 960 MANUAL 8 9 3 6 5 4 2 1 7 1 Body 2 Aerator 3 Anti rotation plate 4 Fixing nut 5 Flow restrictor 6 Solenoid valve assembly 7 Filter 8 Solenoid valve cable 9 Power supply unit PSU...

Страница 6: ...BR ELE Mains Brushed Brass TSL 960 BZ ELE Mains Brushed Bronze Light Reflectance Values Brushed Stainless Steel 58 Brushed Copper 19 Brushed Black 3 Brushed Brass 40 Brushed Bronze 17 Technical Data M...

Страница 7: ...ater Ingress PSU IP67 Cable Lengths Connection to sensor cable 400mm Connection to fused supply 1 5m Technical Data Sensor Sensor Type Infra red Pre set Sensor Range 120mm Maximum Sensor Range 250mm C...

Страница 8: ...0 5bar is required for valve to function Gravity fed installations may require the installation of a booster pump to achieve the optimum operating pressure 3 All pipework must be flushed through prior...

Страница 9: ...SENSOR 30 182 79 175 10MM MIN 35MM MAX M32 PROVIDE 34MM THROUGH HOLE SENSOR CONNECTOR LEAD TO POWER SUPPLY 400MM LEAD LENGTH POWER SUPPLY SOLENOID VALVE 200MM LENGTH SENSOR CONNECTOPR CABLE TO SOLENOI...

Страница 10: ...rface for installation how to install Tap Installation 2 Drill 35mm diameter hole in countertop 3 Insert the tap through hole in basin or countertop 4 Slide the anti rotation plate and fixing nut over...

Страница 11: ...he holes provided Tap Installation 6 Slide the backnut over the flexible hose and sensor leads Tighten using a spanner 7 Position the power supply to the underside of the unit Before fixing into place...

Страница 12: ...Before fixing into place ensure cables can reach the connector positions Tap Installation 10 Connect the solenoid cable connector leads to the solenoid valve 11 Connect the solenoid cable connector to...

Страница 13: ...roduct is now ready to be wired into the spur and tested and commissioned accordingly 14 Once all nuts are tightened open the water inlet and allow water to flow WARNING Ensure all connections are ful...

Страница 14: ...and reconnect the power supply 3 Position your hand less than 5cm in front of the sensor whilst the LED flashes 4 When the LED is contiuously lit and no longer flashing position your hand at the new...

Страница 15: ...scale in solenoid valve Remove solenoid and clean or replace valve Cables between PSU and solenoid are disconnected Reconnect cables Solenoid valve is incorrectly connected polarity reversed Reconnec...

Страница 16: ...ning bathroom tiles the taps should be protected from any splattering of harsh cleansers All grades of stainless steel will stain or discolour if due care and attention is not taken The surface must b...

Страница 17: ...the brass fitting attached to the mains water supply 4 Remove the filter from the faulty solenoid valve 5 Re fit new filter to replacement solenoid valve 6 Reassemble the parts as shown 7 Restore the...

Страница 18: ...s found in normal use The Splash Lab will at their discretion repair provide a replacement part or product or make appropriate adjustments Damage caused by accident misuse or abuse is not covered by t...

Страница 19: ...TSL 960 MANUAL 19 contact General information info thesplashlab com 44 0 161 482 7000 Technical support technical thesplashlab com For further contact information visit www thesplashlab com...

Страница 20: ...TSL 960 EUR REV 1 24 08 20...

Отзывы: