![The Splash Lab TSL.960 Series Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/the-splash-lab/tsl-960-series/tsl-960-series_installation-and-maintenance_1100792015.webp)
TSL.960
MANUAL 15
troubleshooting
Problem
Water not flowing
Cause
Range is too short
Solution
Increase detection range
Range is too long
Decrease detection range
Sensor is dirty or obstructed
Clean sensor and remove obstruction
Tap is in security time-out mode
Replace batteries or restore power supply
Solenoid valve is incorrectly connected
(polarity reversed)
Reconnect solenoid valve with correct
polarity
Sensor is detecting reflections from basin
or another object
Reduce detection range or remove object
causing reflection
Water flow does not stop when user’s hands
are within range
Debris or scale in solenoid valve
Remove solenoid and clean or replace valve
Cables between PSU and solenoid are
disconnected
Reconnect cables
Solenoid valve is incorrectly connected
(polarity reversed)
Reconnect solenoid valve with correct
polarity
Water supply pressure is too high
Reduce water pressure
Slow response time when opening or closing
solenoid valve
Cable connections loose.
Check all connections are properly fitted
together
Debris or scale in solenoid valve
Remove solenoid and clean and
replace valve
Sensor is detecting reflections from basin
or other object
Reduce detection range or remove object
causing reflection
Water flow reduced
Aerator is blocked with scale or debris
Remove aerator and clean or replace
Debris or scale in solenoid valve.
Remove solenoid and clean and
replace valve
Содержание TSL.960 Series
Страница 1: ...TSL 960 deck mounted sensor tap installation maintenance...
Страница 20: ...TSL 960 EUR REV 1 24 08 20...