The Fredericks Company l 2400 Philmont Ave ● HuntingdonValley, PA 19006-0067
Tel: 215.947.2500 l Fax: 215.947.7464 l Email: [email protected] l www.frederickscom.com
1-6200-008_im Revision: B
Page 2 of 4
2.3 Board layout
Below is a drawing showing the board layout,
Sensor configuration
Description
Dual Axis sensor mounted
on board
(standard configuration)
Dual axis sensor is mounted in location L1
R5 is 10.0K ohms
R6 is not installed
Single axis sensors
mounted off board
Single axis sensors are connected to J3 (x-axis) and J4 (Y-axis)
No sensor is installed in L1
R5 is not installed
R6 is 1.0K ohms
Note: If R5 is not removed then R6 must be less than 100 Ohms
Note: J2 is for factory use only.
J1 SIGNAL CONNECTOR
PIN 1
J3 X-AXIS
X-axis
X-AXIS
J4 Y-AXIS
AAAAAXIS
AXIS
L1
DUAL
AXIS
SENSOR
SENSOR
R6
R5