1-6200-008_im Revision: B 

 

Page 1 of 4

 

 

 

 

 

Operating Manual 

 

1-6200-008 
RS485 mini signal conditioner board  

 

 

 

 

 

 

 

 

1.

 

PRODUCT DESCRIPTION 

The RS-485 signal conditioner utilizes Fredericks single and dual axis electrolytic tilt sensors. The 
signal conditioner provides the necessary excitation to the sensor and signal conditioning of the 
output to communicate over a RS485 interface. 

Standard industrial RS-485 interface enables long transmission distances and possibility to connect 
multiple modules, with individual addresses, to the same bus. In addition to tilt angle, temperature 
information is also available from the module that can be used for temperature compensation of 
the sensor. 

2.

 

INSTALLATION  

2.1 Mounting 

The board in mounted in a horizontal position when a sensor in installed into the board. If external 
single axis sensors are connected thru cables, then the board can be mounted in any position. 
Following are the board dimensions, 

Board dimensions...................................................1.25 x 1.25 inches or 32mm x 32mm square  
Mounting hole and spacing..................0.089 inches diameter and 1.05 inches (center to center) 
 

          2.2 Electrical connections 

Below is a table of the power and signal pin-outs, 

Pin #  Signal name 

Direction 

Description 

Vcc 

Input 

Supply voltage input: +3 to +5 vdc regulated 

GND 

Ground - The reference for the digital signals and the supply voltage 

GND 

Ground - The reference for the digital signals and the supply voltage 

TX 

Bi-directional 

RS485 – B 

RX 

Bi-directional 

RS485 – A 

GND 

Ground - The reference for the digital signals and the supply voltage 

GND 

Ground - The reference for the digital signals and the supply voltage 

 

SUNSTAR传感与控制 http://www.sensor-ic.com/ TEL:0755-83376549 FAX:0755-83376182 E-MAIL:[email protected]

SUNSTAR传感与控制 http://www.sensor-ic.com/ TEL:0755-83376549 FAX:0755-83376182 E-MAIL:[email protected]

Содержание RS485

Страница 1: ...board in mounted in a horizontal position when a sensor in installed into the board If external single axis sensors are connected thru cables then the board can be mounted in any position Following are the board dimensions Board dimensions 1 25 x 1 25 inches or 32mm x 32mm square Mounting hole and spacing 0 089 inches diameter and 1 05 inches center to center 2 2 Electrical connections Below is a ...

Страница 2: ...n L1 R5 is 10 0K ohms R6 is not installed Single axis sensors mounted off board Single axis sensors are connected to J3 x axis and J4 Y axis No sensor is installed in L1 R5 is not installed R6 is 1 0K ohms Note If R5 is not removed then R6 must be less than 100 Ohms Note J2 is for factory use only J1 SIGNAL CONNECTOR PIN 1 J3 X AXIS X axis X AXIS J4 Y AXIS AAAAAXIS AXIS L1 DUAL AXIS SENSOR SENSOR ...

Страница 3: ...or factory default for setting up the communications Function Setting Comments Baud rate 9600 factory default Settable from 1200 to 38400 Number of data bits 8 Fixed No parity N Fixed Number of stop bits 1 Fixed 3 COMMANDS 3 1 Command format The following is the command format to read the sensor output and board temperature XXYY start of string XX address YY command end of string a Data commands C...

Страница 4: ...ormation entered by the user 9984Z Zero unit to current position Ver 2 0 Zeroing 9984R Reset zero clears offset value Ver 2 0 Resetting zero 9988Rx x code for baud rate Code Rate 1 1200 2 2400 3 4800 4 9600 5 19200 6 38400 none 9989B Reset to factory defaults Address 99 Baud rate 9600 none Note There is a hardware reset if the baud and or address is unknown This is done by placing a short on R9 on...

Отзывы: