AS/NZS2918:2001 General Notes
(if applicable)
WARNING: DO NOT USE FlAMMABlE lIQUIDS OR AEROSOlS TO START OR REKINDlE THE FIRE.
WARNING: DO NOT USE FlAMMABlE lIQUIDS OR AEROSOlS IN THE VICINITY OF THIS
APPlIANCE WHEN ITS OPERATING.
WARNING: DO NOT STORE FUEl WITHIN HEATER INSTAllATION ClEARANCES.
WARNING: WHEN OPERATING THIS APPlIANCE AS AN OPEN FIRE USE A FIRE SCREEN.
CAUTION: THIS APPLIANCE SHOULD BE MAINTAINED AND OPERATED AT ALL TIMES IN ACCORDANCE WITH THESE INSTRUCTIONS.
CAUTION: THE USE OF SOME TYPES OF PRESERVATIVE-TREATED WOOD AS A FUEL CAN BE HAZARDOUS.
4.R.1H
MODEL
MINIMUM VENT SIZE (x2)
Square Design (l x H)*
Rectangle Design (l x H)*
440 - 700
100 x 100
200 x 50
850
125 x 100
250 x 50
1050
150 x 100
250 x 100
The Fireplace Ltd recommends that allowances are made for air replacement vents to be located near the
fireplace, to aid combustion and reduce the incidence of back venting. Refer to Table 5. for air vent sizing and
suggested location. Fig. 9 - Location points A,B,C,D are suggested combinations. A minimum of one pair of
air vents is recommended or one large vent, as per location point D.
Note: Allowance to be made for minimum 2 x 80mm dia. PVC inlet ducts from outside to internal vent location.
Air Replacement
A
B
C
D
C
B
A
Table 5.
Fig. 9