Installation Guide 84464 Rev. 2
Installations using the DC power cable (PN 855024-020) are recommended to connect the
yellow ignition line as the primary ON/OFF source. The BDU will only turn OFF with this line,
so it is important to connect to an ignition line in the fuse panel or external switch that is
dedicated to the BDU for operating when the vessel’s main ignition is off. See Figure 2-10 for
further details.
Take special note that when connected to a battery for operation and the yellow ignition line is
tied directly to main power (red line) the only method to power down the BDU will be to turn off
the main power connection on the BDU and this is NOT recommended for normal operation.
Figure 2-10: 24V DC Power Connection