©Copyright Task Force Tips LLC 2012-2019
LIN-060 April 29, 2019 Rev01
7
5.0 NOZZLE CONTROLS
5.1 REMOVABLE STREAM STRAIGHTENER
Stream quality is generally improved with use of an integral stream straightener at the Flip Tip Inlet. The Flip Tip may be used without
the straightener if so desired.
The removable stream straightener is a standard option for 1.5” connections.
Our 2.5” connections utilize an optimized waterway in place of the stream straightener. If so desired, the straightener can still be used
with a special 2.5” coupling (P198). Contact TFT for details.
Stream Straightener
Flip Tip with smooth bore front
flipped down
To remove the straightener, flip
the smooth bore front down,
open valve fully, insert a wooden
dowel or similar tool to push
the straightener out the rear of
the coupling.
Figure 5.1 Removable Stream Straightener
5.2 FLIP TIP LOCK
The front nozzle is locked in both positions. To change positions follow the steps in fi gure 2.5.
Unlock
Flip Down
1
2
Unlock
Flip Up
1
2
Figure 5.2 Using the Flip Tip Lock
WARNING
When the front nozzle is in the down position the sealing surfaces are exposed. Avoid actions
which can damage the sealing surface to prevent possible leakage and repairs.
CAUTION
The Flip Tip pivoting joint is not sealed between the fully up and fully down positions. Shut off
water fl ow before changing the front nozzle position to avoid spraying in unintended directions.