Operating Manual

 

 
 

PSW-2G2F+UPS

 

 

 

Multifunction Gigabit Managed Switch

 

 

with built-in UPS for connection to IP video cameras that 

support IEEE802.3at.

 

 
 

Version 5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание PSW-2G2F+UPS

Страница 1: ...Operating Manual PSW 2G2F UPS Multifunction Gigabit Managed Switch with built in UPS for connection to IP video cameras that support IEEE802 3at Version 5...

Страница 2: ...ducting elements of the power supply unit under voltage It is forbidden to transport the switch with the battery installed in it It is forbidden to connect very low battery voltage at the terminals be...

Страница 3: ...on check 16 2 8 5 Battery installation 16 2 8 6 Control of fans operation 17 3 Technical parameters 18 4 Operating conditions 18 5 Preliminary setting 19 5 1 Resetting the switch to factory settings 1...

Страница 4: ...built in UPS designed for connecting IP video cameras with IEEE802 3at PoE support one camera with 60W power consumption Figure 1 1 two cameras with 30W power consumption each Figure 1 2 Figure 1 1 Co...

Страница 5: ...ed either by pairs with data pairs 1 2 and 3 6 or by free pairs pairs 4 5 and 7 8 simultaneously As a result 60W can be supplied to the camera 30W 30W PoE support for two ports 30W each The switch can...

Страница 6: ...It allows to create unattended IP video surveillance networks Operation in a ring or in a chain configuration Two gigabit ports allow to connect switches in a chain Support of STP RSTP protocols allo...

Страница 7: ...Figure 2 1 2 PSW 2G2F UPS switch internal appearance 7...

Страница 8: ...out of components in PSW 2G2F UPS switch During normal operation CPU indicator should blink intermittently with 2 sec period 1 sec ON 1 sec OFF DEFAULT indicator shall be ON when the device operates w...

Страница 9: ...ameras with power consumption up to 60W 60 W PSW 2G2F UPS Pairs 1 2 and 3 6 IEEE802 3at Pairs 4 5 and 7 8 IEEE802 3at Figure 2 3 1 Power supply scheme over PoE 60W WARNING For operation with BEWARD ca...

Страница 10: ...sients in the power supply circuit according to GOST R 51317 4 11 standard Table 2 4 2 performance criteria B Table 2 4 1 port Degree of severity according to Table 1 GOST R 51317 4 5 Voltage pulse va...

Страница 11: ...per minute polls the IP camera If the switch does not receive a response then a one minute timer is started during this time the poll is repeated every 10 seconds If the camera has not responded withi...

Страница 12: ...nvenient when solving network problems 2 8 Built in UPS 2 8 1 Control of incoming voltage The switch monitors the input voltage If the input voltage is above 260V or below 180 the switch is disconnect...

Страница 13: ...T indicator starts to flash intermittently with 2 sec interval 1 sec ON 1 sec OFF In case of further voltage drop below 42V VBAT indicator turns off and the switch goes into sleep mode to prevent deep...

Страница 14: ...ery battery voltage is above 46V supply voltage is absent The switch operates from the battery battery voltage is below 46V but above 42V supply voltage is absent Blinking of VBAT light diode indicate...

Страница 15: ...2 10 30 1 50 35 1 40 40 1 30 45 1 10 50 1 00 55 0 55 60 0 50 Load is the total power of the cameras loss of power on the twisted cable In the camera documentation the manufacturer normally specifies...

Страница 16: ...ry condition once a year Using a battery with a small residual capacity reduces the uninterrupted operation time of the switch Switch batteries operate in the floating mode The service life of the bat...

Страница 17: ...t the battery terminals with holders WARNING 220 V voltage is supplied to the thermocouple 2 8 6 Control of fans operation The switch is equipped with fans They are switched on only in case of high te...

Страница 18: ...istics nominal voltage 12V capacity 2 2A h dimensions 178 35 61 mm quantity 4 Design dimensions 240x360x120 mm maximum weight 6 kg environmental protection rating IP66 cable glands diameter 4 8 mm 5 d...

Страница 19: ...arate document The switch can be managed from remote stations at any point of the network via a standard Web browser for example Microsoft Internet Explorer The browser is a universal access tool and...

Страница 20: ...to authenticate when you log in Figure 5 3 Entering user name and password Note that the user name and password are case sensitive 5 4 Activation of redundancy protocols If you connect the switches in...

Страница 21: ...6 1 1 Attachment points marking WARNING Drilling of the housing will lead of loss of the switch integrity and as a result loss of product warranty 6 1 2 Mounting on the pole To install PSW 2G2F UPS s...

Страница 22: ...cuit breakers Figure 6 1 3 1 TFortis CrossBox 2 cabinet with PSW 2G2F UPS switch TFortis CrossBox cabinet is purchased separately Note that TFortis CrossBox is recommended but not mandatory To install...

Страница 23: ...ommended to use external optical distribution frames 6 3 Power supply connection The switch is connected to 220V AC source Power supply cable is pulled into the unit trough a cable gland and is connec...

Страница 24: ...tors will exceed nominal current values To prevent false tripping of the circuit breakers it is recommended to choose models with characteristic C for at least 4A current 6 4 Camera connection Camera...

Страница 25: ...number has been changed removed or is illegible if there are internal of external mechanical damages chipping cracking deformation damaged power supply wires cracking or splitting of the terminals si...