background image

 

 

 

19 

7 Installation of the switch 

7.1 Installation of the cabinet on the wall 

The  cabinet  has  four  attachment  points.  Marking  of  the  attachment  points  is 
shown in Figure 7.1.  

 

 

Figure 7.1 Marking of attachment points 

 

IMPORTANT!

  Drilling  of  the  enclosure  will  lead  to  loss  of  the  switch  integrity 

and result in the loss of product warranty. 

Содержание PSW-2G+Hot

Страница 1: ...Multifunction Gigabit Managed Switch with PoE support IEEE802 3at up to 60 W per port for connecting four IP video cameras designed to be used in hot climate PSW 2G Hot Operating Manual Version 1 ...

Страница 2: ...y unit under voltage SFP port operates only at 1000 Mbps Fast Ethernet SFP modules will not operate To ensure proper operation of lightning protection provide proper grounding according to the Electrical Code use a shielded twisted pair with shielded RJ45 connectors use minimum length of the twisted pair and power supply cables ...

Страница 3: ...onal functions 15 3 8 1 Restarting cameras in case of hanging 15 3 8 2 Cable tester 16 3 8 3 Remote camera polling 16 4 Technical specifications 16 5 Operating conditions 17 6 Preliminary setting 17 6 1 Resetting the switch to factory settings 17 6 2 IP address setting 17 6 3 User name and password setting 18 6 4 Activation of redundancy protocols 18 7 Installation of the switch 19 7 1 Installatio...

Страница 4: ...4 1 Purpose PSW 2G Hot device is a multifunction gigabit outdoor managed switch designed for the construction of IP video surveillance networks PSW 2G Hot connection scheme ...

Страница 5: ...e gland The key element of the switch is a high performance chip from Marvell which is able to process large amounts of traffic coming from the IP video cameras The switch can supply any video camera compliant with IEEE802 3af or IEEE802 3at standards up to 60W A built in power supply unit ensures direct connection to 230VAC power supply eliminating the need for an additional power supply unit A b...

Страница 6: ...stem The switch enclosure has a tamper sensor Opening of the cabinet door will generate an alarm message to be sent to the server via SNMP or Syslog protocols The optical distribution frame allows for optical cable splicing inside the switch and connecting it to SFP modules The automatic circuit breaker allows to de energize the switch during configuring and debugging Cameras restart automatically...

Страница 7: ...7 3 Description 3 1 Enclosure External view View with the shield removed Figure 3 1 1 PSW 2G Hot switch Figure 3 1 2 PSW 2G Hot interior ...

Страница 8: ...witch The shield is attached to the enclosure at several points to eliminate heat passage from the external casing into the switch All heat generating components of the switch are connected to the enclosure This allows to dissipate heat from electronic components out of the switch A combination of the above technical solutions allows the switch to operate in hot climate Figure 3 1 3 Switch operati...

Страница 9: ...tails and adapters Figure 3 2 1 Optical distribution frame 3 3 Power supply unit The power supply unit is located under the switch board Access to the power supply unit is limited The power supply unit has an aluminum radiator that is pressed against the back panel of the switch to remove the heat to the switch enclosure ...

Страница 10: ...10 Figure 3 3 Power supply unit 3 4 Switch board The switch board is mounted on an aluminum plate that removes the heat from hot electronic components to the switch enclosure Figure 3 4 1 Switch board ...

Страница 11: ...ory settings press the DEFAULT button and hold it down for about 15 seconds The DEFAULT indicator should set ON at this point 3 4 3 CPU indicator During normal processor operation the CPU indicator should blink in 2 second intervals 1 second ON 1 second OFF 3 4 4 DEFAULT indicator DEFAULT indicator is ON when the device has the factory settings IP 192 168 0 1 ...

Страница 12: ... presence of power supply on the switch boards 3 5 Tamper sensor The optical tamper sensor is located inside the switch Figure 3 5 1 The optical tamper sensor is more reliable than sealed and limit switches because it does not get stuck and does not chatter Its operating principle is simple When the power supply unit is closed a curtain Figure 3 5 2 installed on its cover discontinues the optical ...

Страница 13: ...t switch has built in lightning protection modules that protect Ethernet ports and 230 VAC power circuits from common mode and differential electromagnetic interferences The switches are resistant to powerful microsecond pulse interferences according to GOST R 51317 4 5 as per Table 3 7 1 with performance criteria B temporary disruption of performance or functioning with further recovery without o...

Страница 14: ...PORTANT Grounding of the switch is mandatory for lightning protection 3 7 Automatic circuit breaker The switch is provided with an automatic circuit breaker for ease of maintenance Figure 3 7 Automatic circuit breaker ...

Страница 15: ...al Function section see the Configuration Manual The switch constantly 1 time per minute polls the IP camera If the switch does not receive a response then a one minute timer is started during this time the poll is repeated every 10 seconds If the camera has not responded within a minute the switch removes power from the camera for 10 seconds and supplies it again restarting the camera If the came...

Страница 16: ... particular cable which can affect the accuracy of the measurement To improve the accuracy of the cable tester it is recommended to calibrate it Note that calibration is not recommended for cables shorter than 10 meters 3 8 3 Remote camera polling Using the switch it is possible to ping any device on the network through the web interface which is convenient when solving network problems 4 Technica...

Страница 17: ... 1 Resetting the switch to factory settings Before start set the switch to default settings To do this press and hold the DEFAULT button until the DEFAULT indicator is ON The default IP address of the switch is 192 168 0 1 6 2 IP address setting All software functions of the switch can be managed configured and monitored using the built in WEB interface and Telnet Below is the description of WEB b...

Страница 18: ...enter the IP address http 192 168 0 1 Figure 6 2 Entering the IP address of the switch 6 3 User name and password setting Until the user name and password are set you will log in without entering this data After the password is set you will need to authenticate when you log in Figure 6 3 Entering user name and password IMPORTANT Note that the user name and password are case sensitive 6 4 Activatio...

Страница 19: ...n the wall The cabinet has four attachment points Marking of the attachment points is shown in Figure 7 1 Figure 7 1 Marking of attachment points IMPORTANT Drilling of the enclosure will lead to loss of the switch integrity and result in the loss of product warranty ...

Страница 20: ...ame For ease of operation the optical distribution frame can be removed from the cabinet The optical cable is pulled into PG13 5 cable glands The optical cable is attached to the metal base of the distribution frame with nylon ties Optical fibers are laid in a splice cassette for 12 shrinkable plastic sleeves Welded pigtails are connected to SC adapters located on the adapter panel Then the adapte...

Страница 21: ...nected to the automatic circuit breaker The grounding wire is connected to a special grounding screw Figure 7 4 Connection scheme IMPORTANT Grounding of the switch is mandatory Grounding resistance should not exceed 4 Ohm 7 5 Camera connection Camera connection recommendations 1 use a 4 pair shielded twisted pair at least category 5 2 use shielded RJ45 connections ...

Страница 22: ...he enclosure is missing or if the serial number has been changed removed or is illegible if there are internal of external mechanical damages chipping cracking deformation damaged power supply wires cracking or splitting of the terminals signs of treatment with aggressive chemicals or fluids severe contamination insects presence or signs of insects presence in case of improper connection and opera...

Страница 23: ...video surveillance systems operation and adjustment of equipment call 8 a m to 4 p m Moscow time 7 342 270 112 8 7 342 260 20 30 send an e mail to tfortis fort telecom ru All technical documentation is available at https tfortis com support dokumentaciya na produkciyu ...

Отзывы: