5.2. Power supply connection 

 
PSW-1-45-WiFi  switch  is  connected  to  220V  AC  power  supply.  Power 
supply cable is pulled into the unit trough a cable gland and is connected to 
the  power  supply  terminal  block  either  directly  or  via  a  circuit  breaker 
assembly. 
 

WARNING!

  Grounding  of  the  switch  is  required.  Grounding  resistance 

should not exceed 4 Ohm. 
 

WARNING!

 Energized high-voltage conductors should never be in contact 

with  circuit  boards.  The  resulting  failure  will  lead  to  loss  of  product 
warranty. 
 

WARNING! 

The  switch  contains static  power  supply  units  and, therefore,  is  a reactive 
load. Inrush currents that occur during charging of the input capacitors will 
exceed  nominal  current  values.  To  prevent  false  tripping  of  the  circuit 
breakers, it is recommended to choose models with characteristic C and at 
least 4A current. 

5.3. Connecting the cameras and access point 

It  is  recommended  to  use  a  4-pair  shielded  cable,  at  least  category  5. 
Ethernet cable is pulled into the switch through a cable gland, clamped and 
connected  to  RJ45  ports.  For  more  convenient  clamping,  a  cable  gland 
may  be  removed  and  then  re-installed.  Unused  cable  glands  should  be 
sealed off.  

 

 
Figure 5.3.1 Cable termination. 
 

Содержание PSW-1-45-WiFi

Страница 1: ...h conducting elements of the power supply unit under voltage Before connecting a laptop to port 5 of the switch put Passive PoE jumpers into the OFF position For effective lightning protection the fol...

Страница 2: ...2 5 Restarting cameras in case of hanging 8 3 Technical parameters 9 4 Operating conditions 9 5 Installation 10 5 1 Unit mounting 10 5 1 1 Wall mounting 10 5 1 2 Mounting on the pole 11 5 1 3 Installa...

Страница 3: ...et switch used for the construction of IP video surveillance networks 220 VAC 10 100Base Tx 10 100Base TX PoE Figure 1 1 PSW 1 45 WiFi switch connection over twisted pair 220 VAC 10 100Base Tx PoE 24V...

Страница 4: ...r supply is defined by jumpers Passive PoE support 24V Port 5 supports Passive PoE 24V which allows to connect wireless access points such as Ubiquiti or MikroTik Connection to 220V A built in power s...

Страница 5: ...5 2 Description 2 1 Appearance Figure 2 1 1 PSW 1 45 WiFi switch exterior view Figure 2 1 2 PSW 1 45 WiFi switch interior view circuit breakers are not included...

Страница 6: ...6 2 2 Components layout Figure 2 2 Layout of components inside PSW 1 45 WiFi switch During normal processor operation CPU indicator should blink in 2 second intervals 1 second ON 1 second OFF...

Страница 7: ...wer circuits from common mode and differential electromagnetic interferences The switch is resistant to powerful microsecond pulse interferences according to GOST R 51317 4 5 standard with the degree...

Страница 8: ...ge Performance criteria B means temporary disruption of performance or functioning with further recovery without operator s intervention Continued operation with changes in the supply voltage from 187...

Страница 9: ...EE 802 3x flow control support PoE and data transfer distance up to 100 m Power supply PSU voltage 220V 187 to 246V PoE power budget 50W maximum maximum power consumption 60W Design dimensions 240x160...

Страница 10: ...0 C 67 to 122 F 5 Installation 5 1 Unit mounting 5 1 1 Wall mounting The housing has four attachment points at the edges Marking of the attachment points is shown in Figure 5 1 1 226 146 4 PSW 1 45 Wi...

Страница 11: ...tis CrossBox cabinet TFortis PSW 1 45 WiFi switches have a hermetically sealed housing of technopolymer providing IP66 protection rating This ensures safe outdoor installation without the need for an...

Страница 12: ...anty WARNING The switch contains static power supply units and therefore is a reactive load Inrush currents that occur during charging of the input capacitors will exceed nominal current values To pre...

Страница 13: ...illegible if there are internal or external mechanical damages chipping cracking deformation damaged power supply wires cracking or splitting of the terminals signs of treatment with aggressive chemic...

Отзывы: