Programmable Thermostat  type HWPRS 

 

Introduction

Introduction

Introduction

 

 

 

This thermostat can replace any standard room thermostat, and is designed for use with gas or oil heating systems.  If you 
wish to control electric heating note that the current rating is 3A resistive. 
The thermostat is battery-powered and designed for wall mounting, using the backplate supplied.  The HWPRS provides a 
volt-free contact to switch any load up to 3A @ 230V 50Hz and can be positioned wherever you would normally fit a room 
thermostat. 

Set time and weekday:

Set time and weekday:

Set time and weekday:

 

 

 

Insert the batteries into the thermostat; make sure that the batteries are inserted with polarity as indicated in the battery 
compartment.  Press and hold the select and set buttons for 3 seconds.  The hour will flash—adjust with the up or down 
arrow button, confirm with select button.  Adjust the minute and the weekday in the same way.  Press the Set button to 
return to normal running mode. 

Function and wiring of the receiver

Function and wiring of the receiver

Function and wiring of the receiver

 

 

 

1. All wiring should be carried out by a skilled person. Disconnect power before wiring.  Fit a 3 Amp fuse to the receiver 

supply. 

2. The default temperature display shows the current room temperature.  Press the up button until the set temperature is 2 

degrees higher than the current room temperature. 

3. Wait for a few seconds.  The animated flame symbol should be seen in the bottom left-hand corner of the display. 
4. The heating system should now be running. 
5. Press the down button on the transmitter to reduce the temperature below the current room temperature.  Wait for a few 

seconds.  The animated flame symbol should disappear, and the heating should switch off. 

6. If responses do not occur as expected during steps 1—4 above, press the reset button on the thermostat and repeat 

steps 1 – 4. 

Wiring information:

Wiring information:

Wiring information:

 

 

 

Using the crimp connectors and insulating boots provided, connect wiring to the receiver as shown below.   For conven-
tional heating installations, connections will be required to terminals L, SL & Earth.    

Live In 

SL 

Switched Live Output 

Earth 

Earth Park 

Wiring:

Wiring:

Wiring: 

Push button function

Push button function

Push button function

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Key 

Function 

 

Increase setpoint temperature 

 

Decrease setpoint temperature 

 

Turn on backlight for 5 seconds. 
Activate / deactivate Frost Protection 

SET 

Key for confirming and program setting 

SELECT  Key for program setting 

RESET 

System reset 

1

1

1

Отзывы: