TFA 31.1063.01 Скачать руководство пользователя страница 2

Thank you for choosing this product from TFA. 

1. Before you use this product

Please make sure you read the instruction man-
ual carefully. 

Following and respecting the instructions in
your manual will prevent damage to your
instrument and loss of your statutory rights
arising from defects due to incorrect use. We
shall not be liable for any damage occurring as
a result of non-following of these instructions. 

Likewise, we take no responsibility for any
incorrect readings or for any consequences
resulting from them.

Please pay particular attention to the safety
notices!

Please keep this instruction manual safe for
future reference.

2. Delivery contents

Thermocouple measuring device

Stainless steel probe (Cat. No. 30.3535)

Battery 1x CR2032

Instruction manual

3. Range of application and all the benefits of

your new instrument at a glance

Thermocouple measuring device with stainless
steel probe 100 mm (Type K, class 1)

Extra-thin needle probe (1.6 mm) 

Very fast measuring (T90 time approx. 2 sec.)

Ideal for food, liquids, laboratory applications

Display unit protected against water jets (IP 65
standard)

Automatic switch off 

°C/°F reversible 

With magnetic back

4. For your safety

This product is exclusively intended for the range
of application described above. 

It s

hould only be

used as described within these instructions. 

Unauthorised repairs, alterations or changes to
the product are prohibited.

This product is not be used for medical purpose.

Caution! 

Risk of injury!

Wear heat-resistant protective gloves when
touching the hot probe, for example during or
after cooking. 

Risk of burns!

Be careful when handling the pointed probe.

Keep this device and the battery out of reach of
children. 

Batteries contain harmful acids and may be haz-
ardous if swallowed. If a battery is swallowed,
this can lead to serious internal burns and death
within two hours. If you suspect a battery could
have been swallowed or otherwise caught in the
body, seek medical help immediately.

Batteries must not be thrown into a fire, short-
circuited, taken apart or recharged. 

Risk of

explosion!

Low batteries should be changed as soon as pos-
sible to prevent damage caused by leaking. Make
sure the polarities are correct. 

Avoid contact with skin, eyes and mucous mem-
branes when handling leaking batteries. In case
of contact, immediately rinse the affected areas
with water and consult a doctor.

Important information

on product safety!

Do not expose the device to extreme tempera-
tures, vibrations or shocks. 

Do not use the instrument in the microwave,
oven or grill.

The display unit can only be operated within a
temperature range from 0°C…50°C.

Only the probe is heat resistant up to 300 °C. 

Never hold the probe directly over a fire.

Do not immerse the display unit and the connec-
tor in water. Water can penetrate and cause mal-
function. Not suitable for dishwasher.

Do not bend the probe! 

5. Elements

5.1 Display (Fig. 1)

A 1:

Actual temperature

A 2:

Battery symbol

5.2 Buttons (Fig. 1)

B 1:

ON/HOLD 

button

B 2:

°C/°F

button

5.3 Probe (Fig. 1)

C 1:

Insertion probe

C 2:

Probe connector

5.4 Housing (Fig. 1+2)

D 1:

Battery compartment 

D 2:

Socket

D 3:

Magnet

6. Getting started and use

Remove the protective film from the display.

Plug the probe connector into the jack. Make
sure the polarities are correct.

To measure the temperature, insert the probe at
least 2 cm into the object. 

Press the 

ON/HOLD 

button.

The current temperature is seen.

To activate the hold function, press the 

ON/HOLD

button. 

HOLD appears on the display. The actual mea-
sured temperature remains on the display.

Press the 

°C/°F

button in the HOLD mode to

change between °C (Celsius) or °F (Fahrenheit)
as temperature unit.

In the HOLD mode, the device will turn off auto-
matically after 15 seconds.

To deactivate the HOLD function, press again the
ON/HOLD button.

The device will turn off automatically after
approx. 4 minutes. 

Use the integrated magnet at the back of the
device to place it on metal surfaces.

7. Care and maintenance

Clean the device with a soft damp cloth. Do not
use solvents or scouring agents. 

Remove the battery if you do not use the device
for a long period of time.

Store the device in a dry place.

Should water or steam enter the device’s jack, it
could affect the contact with the probe. Dry the
probe connector with a cloth before connecting it
to your instrument.

7.1 Battery replacement

The battery symbol is permanently shown on the
display.

Battery OK

Measurements are possible. 

Weak battery

Please change the battery. 
Measurements are still possible.

Empty battery

Measurements are not possible 
anymore.

Make sure the unit is powered off before chang-
ing the battery. 

Open the battery compartment by turning the lid
to the left using a coin and insert a new battery
CR 2032 (+pole above).

Close the battery compartment by turning the lid
to the right.

8. Troubleshooting

Problem

Solution

No display

Press the 

ON/HOLD 

button to switch on the 

device

Ensure that the battery polarity is correct 
(+pole above)

Change the battery

Er1

Ambient temperature is below 0°C or 
above 50°C

Er2

Large temperature changes in a short time

Er3

Remove the battery 
(Make sure the unit is powered off)

Recommended waiting time: 
at least 60 seconds

Display “Hi/Lo”

Measured temperature is outside the measur-
ing range

Plug in the probe

Check the contact between probe connector 
and jack, dry it if necessary

Incorrect indication

Check the contact between probe connector 
and jack

Check the position of the sensor

Change the battery

If your device fails to work despite these measures,
please contact the retailer where you purchased the
product from for advice. 

9. Waste disposal

This product and its packaging have been manufac-
tured using high-grade materials and components
which can be recycled and reused. This reduces waste
and protects the environment. Dispose of the packag-
ing in an environmentally friendly manner using the
collection systems that have been set up.

Disposal of the electrical device

Remove non-permanently installed
batteries and rechargeable batteries
from the device and dispose of them
separately.
This product is labelled in accor-
dance with the EU Waste Electrical
and Electronic Equipment Directive
(WEEE). 
This product must not be disposed
of in ordinary household waste. As a
consumer, you are required to take
end-of-life devices to a designated
collection point for the disposal of
electrical and electronic equipment,
in order to ensure environmentally-
compatible disposal. The return ser-
vice is free of charge. Observe the
current regulations in place!

Instruction manual

Digital probe thermometer

Cat. No. 31.1063.01

Instruction manuals

www.tfa-dostmann.de/en/service/downloads/
instruction-manuals

Disposal of the batteries 

Never dispose of empty batteries and
rechargeable batteries with ordinary
household waste. They contain pollu-
tants such as heavy metals, which
can be harmful to the environment
and human health if disposed of
improperly, and valuable raw mate-
rials such as iron, zinc, manganese
or nickel that can be recovered from
waste. 
As a consumer, you are required by
law to take them to your retail store
or to an appropriate collection site
depending on national or local regu-
lations in order to protect the envi-
ronment. The return service is free of
charge. You can obtain addresses of
suitable collection points from your
city council or local authority. 

The symbols for the contained heavy
metals are: 
Cd=cadmium, Hg=mercury, Pb=lead.

Reduce the generation of waste from
batteries by using batteries with a
longer lifespan or suitable recharge-
able batteries. Avoid littering the
environment and do not leave batter-
ies or battery-containing electrical
and electronic devices lying around
carelessly. The separate collection
and recycling of batteries and
rechargeable batteries make an
important contribution to relieving
the impact on the environment and
avoiding health risks.

WARNING! 
Environmental and health damage 
caused by incorrect disposal of

batteries!

WARNING! 
Batteries containing lithium 

can explode!

Batteries and rechargeable batteries containing
lithium (Li=lithium) present a high risk of fire and
explosion due to heat or mechanical damage with
potentially serious consequences for people and
the environment. Pay particular attention to 
correct disposal. 

10. Specifications

Thermocouple sensor

Measuring range temperature

-20 °C… 300 °C / -4…+572°F

Accuracy

±0.8 °C …20...80 °C, otherwise ±1.5°C

Resolution

0.1 °C

Dimensions

132 x 16 x 7 mm

Weight

7 g (device only)

Thermocouple measuring device

Operating environment

0°C…50°C / 32°F…122 °F

Protection class 

IP 65

Power consumption

1 x Button cell battery CR2032

Dimensions

42 x 20 x 78 mm

Weight

49 g (device only)

TFA Dostmann GmbH & Co. KG, 
Zum Ottersberg 12, 97877 Wertheim, Germany

No part of this manual may be reproduced without written con-
sent of TFA Dostmann. The technical data are correct at the
time of going to print and may change without prior notice.
The latest technical data and information about this product can
be found in our homepage by simply entering the product num-
ber in the search box.

www.tfa-dostmann.de

09/22

Fig. 1

Fig. 2

A 1

A 2

C 1

D 2

C 2

B 1

B 2

D 1

D 3

TFA_No. 31.1063_Anleitung  14.09.2022  14:18 Uhr  Seite 2