23
22
Küchen-Chef –
Digital BBQ meat / oven thermometer
• Confirm the setting with the
ALARM
button.
• “- -” appears on the oven temperature display and the symbol
and the alarm symbol
flash.
• To activate the upper oven temperature alarm press the
ON/OFF
button. The alarm symbol
appears.
• 70°C (default) or the last adjusted value flashes on the display.
• You can use the
+
or
–
button to set the upper temperature limit.
• Confirm the setting with the
ALARM
button.
• “- -” appears on the oven temperature display and the symbol
and the alarm symbol
flash.
• To activate the lower oven temperature alarm press the
ON/OFF
button. The alarm symbol
appears.
• 0°C (default) or the last adjusted value appear on the display. You can use the
+
or
–
button to set the lower temperature
limit.
• Confirm the setting with the
ALARM
button.
7.3 In case of alarm
• The device will alert you with a beep:
• As soon as the core temperature is reached
• If the set upper temperature limit in the cooking chamber is exceeded
• If the set lower temperature limit in the cooking chamber has fallen below
• The backlight turns on.
Küchen-Chef –
Digital BBQ meat / oven thermometer
• Press any button to stop the alarm sound.
• The alarm symbol
will continue flashing until the measured core temperature has fallen below the set temperature
limit or until the measured oven temperature is within the alarm limits.
• The alarm sound automatically turns off after 3 minutes if not stopped manually.
• To turn off the alarm functions, press the
ON/OFF
button in the respective alarm mode. The alarm symbol
appears.
8. Care and maintenance
• Clean the instrument and the probe with a soft damp cloth. Do not use solvents or scouring agents. Protect it from mois-
ture.
• Should water or steam enter the device’s jack, it could affect the contact with the probe. Dry the probe connector with a
cloth before connecting it to your instrument.
• Turn off the instrument after use.
• Remove the batteries if the device will not be used for an extended period of time.
• Keep the device in a dry place.
8.1 Battery replacement
• Change the batteries when the battery symbol appears on the display.
• Open the battery compartment and insert two new AAA 1.5 V batteries, polarity as illustrated.
• Close the battery compartment again.