GB-20
JACOBSEN G PLEX II Series: ZV
MAINTENANCE AND PARTS MANUAL
GB
1
3
2
VIEW FROM
UNDER
THE SEAT
MOW
POSITION
N
BACKLAP
POSITION
Figure 36
2. Backlap Valve
3. Reel Control Lever
2.
Set the reel control lever to the right for
the backlap position (See Fig. 36).
1.
Start the engine and set the throttle to low
idle. Switch the reel enable switch to the
on position. Lower heads by moving the
mow/lift pedal to the ”mow” position.
2.
Slowly turn the restriction valve knob
clockwise until the desired reel rotation
speed is attained. It should be slow
enough so that the reel will not throw off
the backlapping compound as it spins.
3.
Apply an even coat of backlapping
compound to the entire length of each
blade of the reel. Use a brush with a long
enough handle to keep you away from the
rotating blades. For best results, use a
handle length which will permit application
of compound while standing in front of the
unit.
4.
Once all the blades on the reel are
uniformly sharp, shut off the engine and
switch the reel enable switch to the off
position. Set the reel valve control to the
mow position and close the restriction
valve (all the way clockwise).
NOTICE
•
To ensure proper reel rotation, make sure
the restriction valve is completely closed.
5.
Wash all of the backlapping compound
from all of the heads. Once they are
thoroughly cleaned and dry, apply a light
film of oil to the cutting edges to help
prevent rust.
6.
After backlapping, the bedknife adjustment
should be made again.
STORAGE
WARNING
•
To prevent possible explosion or ignition of
vaporized fuel, DO NOT store equipment
with fuel in tank or carburetor in enclosure
with open flame. (Example: Furnace or
water heater pilot light).
DAILY STORAGE
After each days use:
1.
Clean and inspect the cutting heads.
2.
Check engine oil and hydraulic oil levels.
Fill to proper level as required.
3.
Check for loose or missing hardware.
Tighten or replace as required.
EXTENDED STORAGE
Before storing the unit for an extended period of
time (30 days or more):
1.
While engine is warm, drain the crankcase
oil and remove oil filter, install new oil filter
and fill crankcase with the proper weight of
oil corresponding to the season when the
equipment will next be used. Start the
engine and run for a few minutes to allow
the fresh oil to distribute throughout the
engine.
2.
Drain all fuel from fuel tank and lines.
To put the unit back into operation after an extended
period of storage:
1.
Check crankcase oil and hydraulic oil
levels.
2.
Check coolant level in radiator (diesel).
3.
Fill fuel tank. (diesel-bleed the fuel
system, see Bleeding The Fuel System,
Page 12).
4.
Start the engine and check all connections
for fuel leaks.
Содержание JACOBSEN G-Plex II
Страница 2: ...2000 Textron Inc All Rights Reserved...
Страница 24: ...GB 22 JACOBSEN G PLEX II Series ZV MAINTENANCE AND PARTS MANUAL GB...
Страница 35: ...Parts 10 JACOBSEN G PLEX II Series ZV MAINTENANCE AND PARTS MANUAL 5A FUEL HYDRAULIC RESERVOIRS SUPPORT FRAME...
Страница 37: ...Parts 12 JACOBSEN G PLEX II Series ZV MAINTENANCE AND PARTS MANUAL 5b HYDRAULIC TANK FITTINGS...
Страница 89: ...Parts 64 JACOBSEN G PLEX II Series ZV MAINTENANCE AND PARTS MANUAL 25 REEL ASSEMBLY 1...
Страница 91: ...Parts 66 JACOBSEN G PLEX II Series ZV MAINTENANCE AND PARTS MANUAL 26 REEL ASSEMBLY 2...
Страница 93: ...Parts 68 JACOBSEN G PLEX II Series ZV MAINTENANCE AND PARTS MANUAL 27 REAR ROLLER...
Страница 95: ...Parts 70 JACOBSEN G PLEX II Series ZV MAINTENANCE AND PARTS MANUAL 28 REAR ROLLER...
Страница 119: ......
Страница 120: ......