Textron Greenlee EHP700L Скачать руководство пользователя страница 3

EHP700L Battery-powered Pump

Greenlee / A Textron Company

4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070

3

IMPORTANT SAFETY INFORMATION

SAFETY 

ALERT 

SYMBOL

This symbol is used to call your attention to hazards 

or unsafe practices which could result in an injury or 

property damage. The signal word, defined below, 

indicates the severity of the hazard. The message 

after the signal word provides information for pre-

venting or avoiding the hazard.

Immediate hazards which, if not avoided, WILL result 

in severe injury or death.

Hazards which, if not avoided, COULD result in 

severe injury or death.

Hazards or unsafe practices which, if not avoided, 

MAY result in injury or property damage.

Read and understand all of the 

instructions and safety information 

in this manual before operating or 

servicing this tool.
Failure to observe this warning will 

result in severe injury or death.

Do not connect the pump to any system or system 

component other than those supplied by Greenlee. 

Other manufacturers’ components may not with-

stand the maximum pressure and may fail. Nearby 

 personnel can be injured by flying components and 

hydraulic oil.
Failure to observe this warning will result in severe 

injury or death.

Do not alter the internal high-pressure relief valve 

setting. Altering this setting will change the maximum 

pressure the pump can develop, which can cause a 

component failure. Nearby personnel can be injured 

by flying components and hydraulic oil.
Failure to observe this warning will result in severe 

injury or death.

Do not use this pump in a hazard-

ous environment. Hazards include 

flammable liquids, gases, or other 

materials. Using this pump in a 

hazardous environment can result in 

a fire or explosion.
Failure to observe this warning will 

result in severe injury or death.

When punching thin sheet metals and soft materials 

such as plastics, the operator must stop the pump 

manually. Automatic shut off may not work. 
Failure to observe this warning will result in severe 

injury or death.

Содержание Greenlee EHP700L

Страница 1: ...nderstand all of the instructions and safety information in this manual before operating or servicing this tool Register this product at www greenlee com 52062054 REV 1 2012 Greenlee Textron Inc 8 12...

Страница 2: ...l This manual is intended to familiarize all personnel with the safe operation and maintenance procedures for the Greenlee EHP700L Battery powered Pump Keep this manual available to all personnel Repl...

Страница 3: ...t the pump to any system or system component other than those supplied by Greenlee Other manufacturers components may not with stand the maximum pressure and may fail Nearby personnel can be injured b...

Страница 4: ...g this tool Failure to wear eye protection could result in serious eye injury from flying debris or hydraulic oil Inspect pump hoses couplers and fittings for wear or damage Replace worn damaged or mi...

Страница 5: ...o not allow anything to contact the battery terminals Do not immerse the batteries in liquid Liquid may create a short circuit and damage the battery If batteries are immersed contact your service cen...

Страница 6: ...0 76 l Maximum Operating Pressure 10 000 psi 700 bar Operating Temperature Range 10 F to 104 F 12 C to 40 C Dual Stage Pumping Action Rapid Advance 0 9 l min At Full Pressure 0 3 l min 1 3 8 Female C...

Страница 7: ...coustical and optical warning signals in case of a detected fault The pump can be operated and transported in all positions without any oil leakages This tool is equipped with a circuit board incorpor...

Страница 8: ...sult in severe injury or death Skin injection hazard Do not use hands to check for leaks Depressurize hydraulic system before servicing or disconnecting the hose High pressure oil easily punctures ski...

Страница 9: ...r Crimping pressure has not been reached while motor was running Flashing light and audible alert for 1 second after cycle Error Required crimping pressure has not been reached Operator has interrupte...

Страница 10: ...stments must be done by an authorized service center Daily Before use 1 Inspect the tool for wear or damage such as cracks gouges or chips 2 Inspect the tool for damage or leaks After use 1 Use a damp...

Страница 11: ...act button simultaneously Run for approximately 10 seconds and then attempt to cut If unsuccessful return tool to a Greenlee Authorized Service Center Cold oil Start pump and hold retract button simul...

Страница 12: ...109 2988 USA 815 397 7070 12 Illustration Main 32 23 11 7 4 24 25 26 27 28 29 30 31 2 3 22 21 20 18 9 15 16 14 16 13 16 17 All housing screws screwed in completely T 2 5 Nm max T 8 Nm max 12 32 19 1 1...

Страница 13: ...25 Ring backup piston 1 26 52062193 Fitting 90 1 27 52060735 Cover 1 28 Screw 1 Key Part No Description Qty 29 52062228 Adapter 1 30 52062194 Coupler 3 8 female 1 31 52062241 Coupler cap 1 32 52062237...

Страница 14: ...2 8 4 3 5 6 9 2 T 1 5 Nm max 5 T 1 5 Nm max 4 1 3 52062196 Release lever unit 1 Release lever 1 2 Screw 1 3 Compression spring 1 4 Bolt 1 5 Nut 1 Key Part No Description Qty 52049231 Motor gearbox un...

Страница 15: ...6 Spring 1 7 Valve seat 1 8 O ring 1 52062238 Seal kit includes items marked with 52062239 Fastener kit includes items marked with 52062231 Pump housing cap 1 Cap 1 2 52062234 Sleeve 1 3 Seal ring 1 4...

Страница 16: ...ew plug 1 3 Piston seal 1 4 Washer 1 5 Pump piston 1 6 Valve stem 1 7 Spring 1 52062238 Seal kit includes items marked with Key Part No Description Qty 1 2 3 6 7 8 10 9 5 4 52049232 Relief valve unit...

Страница 17: ...t Reservoir Assembly 52062180 Reservoir assembly 1 52062217 Reservoir 1 2 Seal 2 3 Reservoir shaft 1 4 52055861 Clamp 10 pack 2 5 Bolt shoulder 2 6 O ring 1 7 Adapter 1 8 Reservoir plate 1 52062238 Se...

Страница 18: ...1 Front panel 1 2 Control shaft 1 3 Screw 6 4 Board 1 5 Pin 1 6 Washer 2 7 Standoff 2 8 Knob 1 9 LCD display 1 Key Part No Description Qty 10 Switch 1 11 Retaining ring 1 12 Contact cover 1 13 Contact...

Страница 19: ...EHP700L Battery powered Pump Greenlee A Textron Company 4455 Boeing Dr Rockford IL 61109 2988 USA 815 397 7070 19...

Страница 20: ...8 USA 815 397 7070 An ISO 9001 Company Greenlee Textron Inc is a subsidiary of Textron Inc USA Tel 800 435 0786 Fax 800 451 2632 Canada Tel 800 435 0786 Fax 800 524 2853 International Tel 1 815 397 70...

Отзывы: