Ground or Leakage Current
Contact Voltage
Range
Resolution
Accuracy
0.010 to 0.10 Ω
0.001 Ω
± (1.5% + 0.01 Ω)
0.10 to 1.00 Ω
0.01 Ω
± (1.5% + 0.02 Ω)
1.0 to 50.0 Ω
0.1 Ω
± (1.5% + 0.1 Ω)
50.0 to 100.0 Ω
0.5 Ω
± (2.0% + 0.5 Ω)
100 to 200 Ω
1 Ω
± (3.0% + 1 Ω)
200 to 400 Ω
5 Ω
± (5.0% + 5 Ω)
400 to 600 Ω
10 Ω
± (10.0% + 10 Ω)
600 to 1200 Ω
50 Ω
± 20% (approximately)
1200 to 1500 Ω
50 Ω
± 25% (approximately)
Measurement Range
Resolution
Accuracy
0.1 to 5.0V
0.1V
±5% ±0.1V
5.0 to 50.0V
0.5V
±5% ±0.5V
50.0 to 75.0V
1V
±10% ±1V
Measurement Range
Resolution
Accuracy
0.1 to 1.000mA
0.1µA
±2% ±50µA
1.000 to 3.000mA
3.00 to 10.00mA
10µA
±2% ±50µA
10.00 to 30.00mA
30.0 to 100.0mA
100µA
±2% ±100µA
100.0 to 300.0mA
0.300 to 1.000A
1mA
±2% ±1mA
1.000 to 3.000A
3.00 to 39.99A
10mA
±2% ±10mA
Ground Resistance