background image

Greenlee / A Textron Company

2

4455 Boeing Dr. • Rockford, IL 61109-2988 USA • 815-397-7070

1725 Hydraulic Foot Pump

All specifications are nominal and may change as design improve-
ments occur. Greenlee Textron Inc. shall not be liable for damages
resulting from misapplication or misuse of its products.

KEEP THIS MANUAL

Table of Contents

Description ..................................................................... 2

Safety ............................................................................. 2

Purpose of this Manual .................................................. 2

Important Safety Information ...................................... 3–4

Preparation ..................................................................... 5

Operation ....................................................................... 5

Filling the Reservoir with Hydraulic Oil ........................... 5

Purging Air from the System .......................................... 6

Maintenance ................................................................... 6

Troubleshooting ............................................................. 7

Replacing the Valve Pin ................................................. 8

Setting the Relief Pressure ............................................ 8

Repairing an Intake Leak ............................................... 8

Detecting and Repairing a Discharge Leak .................... 8

Refinishing a Ball Seat ................................................... 9

Illustrations and Parts List ........................................ 9–11

Description

The 1725 Hydraulic Foot Pump develops 6500 psi
(44, 818 kPa) and is intended to be used with the
following Greenlee hydraulically powered tools:

Cable Bender: model 800

Cable Cutter: model 750

Punch Drivers: model 1731

model 7606

model 7610

model 7625

Fill with Greenlee hydraulic oil or Mobil DTE-13 only.

Safety

Safety is essential in the use and maintenance of
Greenlee tools and equipment. This manual and any
markings on the tool provide information for avoiding
hazards and unsafe practices related to the use of this
tool. Observe all of the safety information provided.

Purpose of this Manual

This instruction manual is intended to familiarize
operators and maintenance personnel with the 1725
Hydraulic Foot Pump.

Keep this manual available to all personnel.

Replacement manuals are available upon request at no
charge.

Содержание GREENLEE 1725

Страница 1: ...MANUAL 1725 Hydraulic Foot Pump 999 8293 5 2005 Greenlee Textron Inc IM 994 REV 10 5 05 Read and understand all of the instructions and safety information in this manual before operating or servicing...

Страница 2: ...g a Ball Seat 9 Illustrations and Parts List 9 11 Description The 1725 Hydraulic Foot Pump develops 6500 psi 44 818 kPa and is intended to be used with the following Greenlee hydraulically powered too...

Страница 3: ...pressure before disconnecting hoses or couplers and before servicing the pump or accessory Read and understand all of the instructions and safety information in this manual before operating or servici...

Страница 4: ...uctions and safety informa tion supplied with the hydraulic ram or accessory Failure to observe this warning could result in severe injury or death Use this tool for the manufacturer s intended use on...

Страница 5: ...he system 1 Press down on the lever 1 and release Repeat until the operation is complete See Figure 1 2 Press down on the release lever 15 to release the hydraulic pressure See Figure 2 Figure 2 Figur...

Страница 6: ...mes and release Repeat this process several times See Figure 4 4 Set the pump on a horizontal surface and operate the pump as usual If the lever still feels spongy or operation is erratic repeat steps...

Страница 7: ...om the System Worn intake valve seat plug See Repairing an Intake Leak Pump will not build pressure Grit or other foreign matter in hydraulic Disassemble pump Clean all parts system will not allow pro...

Страница 8: ...ension 6 Turn the valve screw 32 clockwise to decrease the relief setting or counterclockwise to increase the relief setting 7 Repeat steps 4 7 until the relief setting is at the correct pressure 8 Ti...

Страница 9: ...ard angle into a drill press 4 Lock the pump block into the vise Be sure the block is level 5 Bring the bit down to the seat and set the depth stop 6 Back the bit off and turn the depth stop up 0 010...

Страница 10: ...5 Boeing Dr Rockford IL 61109 2988 USA 815 397 7070 1725 Hydraulic Foot Pump 1725 Hydraulic Foot Pump Exploded View 2 1 3 4 5 6 7 8 9 10 11 12 32 31 30 29 28 26 19 23 22 21 18 19 20 17 24 25 21 15 13...

Страница 11: ...17 503 1349 5 Plunger release 1 18 905 3355 0 Spring compression Lee LC 022BC 3 discharge check 1 19 905 0678 2 Ball 3 16 grade 25 chrome steel 3 20 905 1337 1 Screw 5 16 24 NF x 5 32 Holo Krome sock...

Страница 12: ...397 1865 Canada 800 435 0786 Fax 800 524 2853 International 1 815 397 7070 Fax 1 815 397 9247 4455 Boeing Drive Rockford IL 61109 2988 USA 815 397 7070 An ISO 9001 Company Greenlee Textron Inc is a su...

Отзывы: