Maintenance

Wear eye protection when operating 

or servicing this tool. 
Failure to wear eye protection could 

result in serious eye injury from 

flying debris or hydraulic oil. 

Skin injection hazard:
Do not use hands to check for oil 

leaks. Oil under pressure easily 

punctures skin. If injured, seek 

medical attention immediately to 

remove oil.
Failure to observe this warning 

could result in serious injury, gan-

grene, or death.

Do not use solvents or flammable 

liquids to clean the tool body. 

Solvents or flammable liquids could 

ignite and cause serious injury or 

property damage.

Pinch points:
•  Remove battery before changing 

dies, adapters, or jaws.

•  Keep hands away from the crimp-

ing tool head when crimping.

Failure to observe these warnings 

could result in severe injury or death.

Relief valve adjustments must be done by an  

authorized service center.

Daily

Before use:

1.  Inspect the tool for wear or damage, such as cracks, 

gouges, or chips.

2.  Inspect the tool for damage or leaks.
3.  Inspect the rotation of the head assembly. Fully 

retract the ram. The head should rotate no more 

than 360°. If damage is detected, send the tool to a 

Greenlee  Authorized Service Center for inspection.

After use:

1.  Use a damp cloth and mild detergent to clean the 

housing. Allow the housing to dry.

2.  Fully retract the ram. Place the tool in the carrying 

case and store in a cool, dry place.

3.  If necessary, recharge the batteries. Refer to the 

instructions supplied with the battery charger.

Monthly

1.  Thoroughly clean all surfaces.
2.  Check the oil level.

Annually or After 10,000 Crimps

1.  Replace the hydraulic oil.
2.  Send the tool to a Greenlee  Authorized Service 

Center for inspection.

Checking the Oil Level

1.  Remove the screws holding the housing cover 

together.

2.  Point the crimping head downward and remove the 

oil reservoir plug. Fill reservoir if necessary.

3.  Replace the oil plug and housing cover.

Note:  For Warranty Service or Repair, contact Greenlee 

customer service at 800-435-0786.

Содержание EK1230L

Страница 1: ...CL Battery powered Crimping Tools 52047657 REV 5 2016 Greenlee Textron Inc 7 16 Read and understand all of the instructions and safety information in this manual before operating or servicing this tool Register this product at www greenlee com ...

Страница 2: ... cable The EK1230CL has a PVC covered crimping head This tool has a retraction stop feature which allows the operator to stop the retraction motion of the ram to shorten cycle time This tool is protected by U S Patent No 6 206 663 6 276 186 6 401 515 and 6 718 870 Safety Safety is essential in the use and maintenance of Greenlee tools and equipment This manual and any markings on the tool provide ...

Страница 3: ...ng this unit on or near energized electrical lines use proper personal protective equipment Failure to observe this warning could result in severe injury or death Wear eye protection when operating or servicing this tool Failure to wear eye protection could result in serious eye injury from flying debris or hydraulic oil Skin injection hazard Do not use hands to check for oil leaks Oil under press...

Страница 4: ... thorough drying when electrical components are soaked Use this tool for the manufacturer s intended purpose only Failure to observe these precautions may result in injury or property damage Do not allow anything to contact the battery terminals Do not immerse the batteries in liquid Liquid may create a short circuit and damage the battery If batteries are immersed contact your service center for ...

Страница 5: ...2 F 15 C to 50 C Crimping Capacities Crimping Range 8 AWG to 750 kcmil Battery Charger Read the instructions supplied with the battery charger EK1230L and EK1230CL 1 LED Work Light white 2 Crimping Head 3 Die Release Buttons 4 Lanyard Ring 5 Housing 6 Retract Button 7 LED Indictor red 8 Battery 9 Trigger 9 8 2 3 4 7 6 5 1 52047087 120 VAC corded adapter 52047088 230 VAC corded adapter 52049189 18 ...

Страница 6: ...ough drying when electrical components are soaked Use this tool for the manufacturer s intended purpose only Failure to observe these precautions may result in injury or property damage Charging the Battery Read the instructions supplied with the battery charger LED Work Light white This LED automatically turns on when the trigger is pulled It remains on for 10 seconds after the trigger is release...

Страница 7: ...ce the dies Continue to crimp until the pressure relief valve activates Note Pressure relief occurs at approximately 106 kN 12 tons and is indicated by an audible pop 8 After achieving pressure relief the ram automatically returns to the start position and the dies retract 9 To stop the ram from returning fully activate the trigger for a brief moment This activation will close the retraction valve...

Страница 8: ...ONNECTOR TYPE Copper Splices Copper Lugs 8 to 1 0 AWG 1 crimp 2 0 AWG to 350 kcmil 2 crimps 400 to 750 kcmil 3 crimps NUMBER OF CRIMPS ANDERSON VACS VACL BLACKBURN ASP ATL BURNDY YS A YA A YA ATN ILSCO AS ASN ACL ACN 2ACL 2ACN ALNS ALNN ALND PANDUIT SA LAA LAB T B 60501 to 60578 60101 to 60176 60230 to 60278 PENN UNION PIK BLUA CONNECTOR TYPE Dual rated Aluminum Splices Dual rated Aluminum Lugs 95...

Страница 9: ... an authorized service center Daily Before use 1 Inspect the tool for wear or damage such as cracks gouges or chips 2 Inspect the tool for damage or leaks 3 Inspect the rotation of the head assembly Fully retract the ram The head should rotate no more than 360 If damage is detected send the tool to a Greenlee Authorized Service Center for inspection After use 1 Use a damp cloth and mild detergent ...

Страница 10: ... warm oil Store tool in warm area Dies stop during operation Oil level low Return tool to a Greenlee Authorized Service Center Air in hydraulic system Pull trigger and hold retract button simultaneously Hold for approximately 10 seconds LED glows for 20 seconds Battery charge low Charge or replace battery Tool loses oil Damaged internal seal Return tool to a Greenlee Authorized Service Center Note...