The storage time for properly charged Lithium-Ion batteries supplied with this vehicle varies based on the ambient
temperature.
Setting State of Charge (SOC)
The optional SOC meter or the hand held programmer may be used to determine the state of charge of the battery
module. If the SOC is below 30%, charge the battery module until the state of charge reaches 50%. The charge cycle
may be interrupted by disconnecting the charger from the AC power source first, then from the charging receptacle on
the vehicle. If the SOC is above 50%, operate the vehicle until the SOC is below 50%.
During Storage
Check the state of charge every 30 days. If the SOC is below 30%, charge the battery module until the state of charge
reaches 50%.
Extreme Low Temperature Storage
If the ambient temperature is below -4°F (-20°C) DO NOT:
• turn the vehicle key to the ON position
• drive the vehicle
• tow the vehicle
• charge the vehicle
• operate accessories
• turn the lights on (if equipped)
Returning Vehicle to Service
At the end of the storage period, charge the battery module to 100% before operating the vehicle.
Before charging the vehicle be sure that the ambient temperature is between 14°F (-10°C) and 113°F (45°C) and the
vehicle has had time to adjust to the temperature.
BATTERY DISPOSAL
Lithium-Ion batteries are recyclable:
• Contact the distributor or manufacturer for information on returning or recycling used or damaged battery
packs.
•Contact local or state environmental department for disposal information.
•Refer to the Maintenance section for additional information.
Temperature
Length of Storage Time
-22°F to -4°F (-30°C to -20°C)
One month at 100% battery charge, all accessories turned off.
-4°F to 113°F (-20°C to 45°C)
Six months at 100% battery charge, all accessories turned off.
113°F to 140°F (45°C to 60°C)
One month at 30% - 50% charge, all accessories turned off.
Содержание Cushman HAULER 800X ELiTE 2019
Страница 1: ...OWNER S GUIDE 678059 C RIVISED JANUARY 2019 ISSUED JULY 2018 HAULER 800X ELiTE...
Страница 12: ...4 INTRODUCTION...
Страница 20: ...12 SAFETY...
Страница 34: ...26 OPERATION Always secure the cargo...
Страница 50: ...42 MAINTENANCE LOG DATE MILES KM AND HOURS TECHNICIAN SERVICE PERFORMED COMMENTS...
Страница 51: ...MAINTENANCE LOG 43 DATE MILES KM AND HOURS TECHNICIAN SERVICE PERFORMED COMMENTS...
Страница 52: ...44 MAINTENANCE LOG DATE MILES KM AND HOURS TECHNICIAN SERVICE PERFORMED COMMENTS...
Страница 53: ...MAINTENANCE LOG 45 DATE MILES KM AND HOURS TECHNICIAN SERVICE PERFORMED COMMENTS...
Страница 54: ...46 MAINTENANCE LOG DATE MILES KM AND HOURS TECHNICIAN SERVICE PERFORMED COMMENTS...
Страница 55: ...APPENDIX A A 1 APPENDIX A BATTERY CHARGER USER S GUIDE...
Страница 58: ...A 4 APPENDIX A...
Страница 59: ...APPENDIX B A APPENDIX B DECLARATION OF CONFORMITY...
Страница 60: ...B APPENDIX B...
Страница 61: ...APPENDIX B C...
Страница 62: ...D APPENDIX B...
Страница 63: ...APPENDIX B E...
Страница 64: ...F APPENDIX B...